As one of the leading manufacturers of Domestic & Industrial Electric Wires and Cables in India, we have always believed in setting higher benchmarks of quality, safety, and reliability.
RBICAB Submersible Motor Power Cables are designed to deliver reliable electrical power to submersible motors operating underwater or in harsh conditions. Made with high-grade electrolytic copper conductors, these cables ensure optimal conductivity, reduced energy loss, and stable performance in deep borewells and submerged applications.
The insulation comprises superior PVC compound, offering high dielectric strength, moisture resistance, and protection against abrasion and chemicals. The flat three-core design provides exceptional flexibility, ease of installation, and space efficiency, enabling smooth operation in tight pipelines and restricted spaces where round cables are unsuitable.
Their robust build ensures mechanical resilience, resistance to environmental factors, and prolonged durability. Featuring consistent insulation thickness and durable sheathing, these cables inhibit leakage, withstand prolonged water exposure, and offer enhanced safety against voltage fluctuations.
Widely employed in irrigation, industrial water supply, and residential borewells, RBICAB Submersible Motor Power Cables are a trusted solution for efficient motor performance. Produced in compliance with global standards, they ensure safety, reliability, and longevity in extreme operating environments.
99.95% EC Grade Copper
High Conductivity
Better Thermal Stability
Abrasion Resistant PVC Compound
High Ageing Property
Impervious to Water, Oil & Grease
Feature | Details |
|---|---|
Conductor | RBICAB High-grade electrolytic copper for excellent conductivity and low power loss |
Insulation | RBICAB Special PVC compound with high electrical strength, moisture & abrasion resistance |
Design | RBICAB Flat 3-core construction for flexibility, easy installation, and compact fitting |
Durability | RBICAB Robust build to withstand continuous immersion in water and harsh environments |
Protection | RBICAB Uniform insulation and sheathing prevent leakage and voltage fluctuation issues |
Applications | RBICAB Agriculture, irrigation, borewells, industrial and domestic water supply |
Standards | RBICAB Manufactured as per international safety and performance standards |
conductor | insulation | sheath | Conductor Resistance @20°C (Max.) Ohms/km | Current Carrying Capacity @ 40°C (Amps) | ||
|---|---|---|---|---|---|---|
Area (nom). sq. mm | no/dia. of stands mm | thickness (nom). mm | overall dimensions | |||
thickness (nom). mm | size (approx.) (WxT) mm | |||||
1.5 | 30/0.25 | 0.8 | 1.1 | 11.4 x 5.3 | 13.3 | 16 |
2.5 | 50/0.25 | 0.9 | 1.2 | 13.3 x 6.0 | 7.98 | 22 |
4 | 56/0.3 | 1 | 1.3 | 16.1 x 7.1 | 4.95 | 29 |
Note: Insulation thickness, sheath thickness and overall dimension given in this table are nominal values. The strand diameter is nominal, however, construction of the conductor is designed to satisfy the requirement of conductor resistance as per IS 8130:2013.
conductor | insulation | sheath | Conductor Resistance @20°C (Max.) Ohms/km | Current Carrying Capacity @ 40°C (Amps) | ||
|---|---|---|---|---|---|---|
Area (nom). sq. mm | no/dia. of stands mm | thickness (nom). mm | overall dimensions | |||
thickness (nom). mm | size (approx.) (WxT) mm | |||||
6 | 84/0.3 | 1.1 | 1.4 | 18.6 x 8.0 | 3.30 | 37 |
10 | 80/0.4 | 1.3 | 1.6 | 23.4 x 10.0 | 1.91 | 51 |
16 | 126/0.4 | 1.4 | 1.8 | 27.0 x 11.4 | 1.21 | 68 |
25 | 196/0.4 | 2.0 | 2.2 | 35.4 x 15.0 | 0.78 | 86 |
35 | 276/0.4 | 2.1 | 2.2 | 39.3 x 16.3 | 0.554 | 110 |
50 | 396/0.4 | 2.2 | 2.4 | 45.7 x 18.5 | 0.386 | 145 |
Note: 3 Core x 70 sq. mm & 3 Core x 95 sq. mm Flat Cable are available on request.
D-18, Site-3, Meerut Road Industrial Area, UPSIDC, Ghaziabad, Uttar Pradesh 201003 (INDIA)