RBICAB Solar DC Cables are engineered specifically for photovoltaic power transmission, providing reliable connectivity between solar panels, inverters, and balance-of-system components. These cables feature high-conductivity tinned copper conductors that minimize energy loss while preventing oxidation for consistent performance.
With UV-resistant, flame-retardant, and weatherproof insulation, RBICAB Solar DC Cables withstand prolonged exposure to sunlight, moisture, ozone, and extreme environmental conditions. The double-layer construction delivers superior dielectric strength and operational safety across wide temperature ranges.
These cables combine mechanical durability with installation flexibility, offering excellent abrasion resistance for rooftop arrays, ground-mounted installations, off-grid systems, and utility-scale solar farms. Their robust design ensures trouble-free performance with minimal maintenance requirements.
Manufactured in compliance with IEC, TUV, and IS standards, RBICAB Solar DC Cables guarantee system efficiency, long-term reliability, and optimal power transmission for solar energy applications.
Conductor: Electrolytic Multi Stranded Tinned Copper Conductor Flexible (As per IEC 60228) Class 5.
Insulation: Crosslinked Halogen Free & Flame Retardant Insulation.
Sheath: Crosslinked Halogen Free & Flame Retardant Sheath (in Black/Blue/Red Colour).
Parameter | Value |
|---|---|
Rated Voltage | 0.6/1 kV AC |
Rated DC Voltage | 1.5 kV |
Maximum DC Voltage | 1.8 kV |
Maximum AC Voltage | 0.7/1.2 kV |
Working Voltage | DC 1000 V |
Insulation Resistance | 1000 MΩ-km |
Spark Test | 6000 Vac (8400 Vdc) |
Voltage Withstand | 6500 V for 5 min (EN50395) |
Ampacity | As per PV system requirements |
Area(Sq. mm) | Conductor Resistance(Ω/km @20°C, Max) | Current carrying capacity (Amp) | Overall Diameter in mm (approx.) | |||
|---|---|---|---|---|---|---|
Single cable(In air) | Single cable(On surface ) | Two cable(On surface) | 2Pfg 1169(As per IS standard) | 2Pfg 1990 and EN 50618(As per IS standard) | ||
2.5 | 8.21 | 41 | 39 | 33 | 5.0 | 6.5 |
4 | 5.09 | 55 | 52 | 44 | 5.5 | 7.0 |
6 | 3.39 | 70 | 67 | 57 | 6.0 | 7.5 |
10 | 1.96 | 98 | 93 | 79 | 7.0 | 8.6 |
16 | 1.24 | 132 | 125 | 107 | 8.0 | 9.9 |
25 | 0.795 | 176 | 167 | 142 | 10.5 | 11.4 |
35 | 0.565 | 218 | 207 | 176 | 11.5 | 12.5 |
Area(sq. mm) | INSULATION Thickness (mm) | SHEATH Thickness(mm) | Overall Diameter(mm) | Tolerance on Diameter | Tinned Copper Maximum Resistance at 20°C(ohms - Ω / km) | Current Carrying Capacity(Single cable in Air) Amps |
|---|---|---|---|---|---|---|
1.5 | 0.7 | 0.8 | 4.8 | +/- 0.4 | 13.700 | 30 |
2.5 | 0.7 | 0.8 | 5.2 | +/- 0.4 | 8.210 | 41 |
4 | 0.7 | 0.8 | 5.8 | +/- 0.4 | 5.090 | 55 |
6 | 0.7 | 0.8 | 6.4 | +/- 0.4 | 3.390 | 70 |
Area(sq. mm) | INSULATION Thickness(mm) | SHEATH Thickness(mm) | Overall Diameter(mm) | Tolerance on Diameter | Tinned Copper Maximum Resistance at 20°C(ohms - Ω / km) | Current Carrying Capacity(Single cable in Air) Amps |
|---|---|---|---|---|---|---|
10 | 0.7 | 0.8 | 7.3 | +/-0.4 | 1.950 | 98 |
16 | 0.7 | 0.9 | 8.6 | +/-0.4 | 1.240 | 132 |
25 | 0.9 | 1.0 | 10.4 | +/-0.4 | 0.795 | 176 |
35 | 0.9 | 1.1 | 11.8 | +/-0.4 | 0.565 | 218 |
50 | 1.0 | 1.2 | 13.8 | +/-0.4 | 0.393 | 276 |
70 | 1.1 | 1.2 | 15.6 | +/-0.4 | 0.277 | 347 |
95 | 1.1 | 1.3 | 17.7 | +/-0.4 | 0.210 | 416 |
120 | 1.2 | 1.3 | 19.5 | +/-0.5 | 0.164 | 488 |
150 | 1.4 | 1.4 | 21.6 | +/-0.5 | 0.132 | 566 |
185 | 1.6 | 1.6 | 24.2 | +/-0.5 | 0.108 | 644 |
240 | 1.7 | 1.7 | 27.1 | +/-0.5 | 0.0817 | 775 |