As one of the leading manufacturers of Domestic & Industrial Electric Wires and Cables in India, we have always believed in setting higher benchmarks of quality, safety, and reliability.
RBICAB Solar DC Cables are engineered specifically for photovoltaic power transmission, providing reliable connectivity between solar panels, inverters, and balance-of-system components. These cables feature high-conductivity tinned copper conductors that minimize energy loss while preventing oxidation for consistent performance.
With UV-resistant, flame-retardant, and weatherproof insulation, RBICAB Solar DC Cables withstand prolonged exposure to sunlight, moisture, ozone, and extreme environmental conditions. The double-layer construction delivers superior dielectric strength and operational safety across wide temperature ranges.
These cables combine mechanical durability with installation flexibility, offering excellent abrasion resistance for rooftop arrays, ground-mounted installations, off-grid systems, and utility-scale solar farms. Their robust design ensures trouble-free performance with minimal maintenance requirements.
Manufactured in compliance with IEC, TUV, and IS standards, RBICAB Solar DC Cables guarantee system efficiency, long-term reliability, and optimal power transmission for solar energy applications.
Conductor: Electrolytic Multi Stranded Tinned Copper Conductor Flexible (As per IEC 60228) Class 5.
Insulation: Crosslinked Halogen Free & Flame Retardant Insulation.
Sheath: Crosslinked Halogen Free & Flame Retardant Sheath (in Black/Blue/Red Colour).
Parameter | Value |
|---|---|
Rated Voltage | 0.6/1 kV AC |
Rated DC Voltage | 1.5 kV |
Maximum DC Voltage | 1.8 kV |
Maximum AC Voltage | 0.7/1.2 kV |
Working Voltage | DC 1000 V |
Insulation Resistance | 1000 MΩ-km |
Spark Test | 6000 Vac (8400 Vdc) |
Voltage Withstand | 6500 V for 5 min (EN50395) |
Ampacity | As per PV system requirements |
Area(Sq. mm) | Conductor Resistance(Ω/km @20°C, Max) | Current carrying capacity (Amp) | Overall Diameter in mm (approx.) | |||
|---|---|---|---|---|---|---|
Single cable(In air) | Single cable(On surface ) | Two cable(On surface) | 2Pfg 1169(As per IS standard) | 2Pfg 1990 and EN 50618(As per IS standard) | ||
2.5 | 8.21 | 41 | 39 | 33 | 5.0 | 6.5 |
4 | 5.09 | 55 | 52 | 44 | 5.5 | 7.0 |
6 | 3.39 | 70 | 67 | 57 | 6.0 | 7.5 |
10 | 1.96 | 98 | 93 | 79 | 7.0 | 8.6 |
16 | 1.24 | 132 | 125 | 107 | 8.0 | 9.9 |
25 | 0.795 | 176 | 167 | 142 | 10.5 | 11.4 |
35 | 0.565 | 218 | 207 | 176 | 11.5 | 12.5 |
Area(sq. mm) | INSULATION Thickness (mm) | SHEATH Thickness(mm) | Overall Diameter(mm) | Tolerance on Diameter | Tinned Copper Maximum Resistance at 20°C(ohms - Ω / km) | Current Carrying Capacity(Single cable in Air) Amps |
|---|---|---|---|---|---|---|
1.5 | 0.7 | 0.8 | 4.8 | +/- 0.4 | 13.700 | 30 |
2.5 | 0.7 | 0.8 | 5.2 | +/- 0.4 | 8.210 | 41 |
4 | 0.7 | 0.8 | 5.8 | +/- 0.4 | 5.090 | 55 |
6 | 0.7 | 0.8 | 6.4 | +/- 0.4 | 3.390 | 70 |
Area(sq. mm) | INSULATION Thickness(mm) | SHEATH Thickness(mm) | Overall Diameter(mm) | Tolerance on Diameter | Tinned Copper Maximum Resistance at 20°C(ohms - Ω / km) | Current Carrying Capacity(Single cable in Air) Amps |
|---|---|---|---|---|---|---|
10 | 0.7 | 0.8 | 7.3 | +/-0.4 | 1.950 | 98 |
16 | 0.7 | 0.9 | 8.6 | +/-0.4 | 1.240 | 132 |
25 | 0.9 | 1.0 | 10.4 | +/-0.4 | 0.795 | 176 |
35 | 0.9 | 1.1 | 11.8 | +/-0.4 | 0.565 | 218 |
50 | 1.0 | 1.2 | 13.8 | +/-0.4 | 0.393 | 276 |
70 | 1.1 | 1.2 | 15.6 | +/-0.4 | 0.277 | 347 |
95 | 1.1 | 1.3 | 17.7 | +/-0.4 | 0.210 | 416 |
120 | 1.2 | 1.3 | 19.5 | +/-0.5 | 0.164 | 488 |
150 | 1.4 | 1.4 | 21.6 | +/-0.5 | 0.132 | 566 |
185 | 1.6 | 1.6 | 24.2 | +/-0.5 | 0.108 | 644 |
240 | 1.7 | 1.7 | 27.1 | +/-0.5 | 0.0817 | 775 |
D-18, Site-3, Meerut Road Industrial Area, UPSIDC, Ghaziabad, Uttar Pradesh 201003 (INDIA)