As one of the leading manufacturers of Domestic & Industrial Electric Wires and Cables in India, we have always believed in setting higher benchmarks of quality, safety, and reliability.
RBICAB LT (Low Tension) Aluminium Cables are specialized electrical cables designed for low-voltage power distribution and wiring applications, typically up to 1.1 kV. These cables provide a cost-effective, efficient, and safe solution for transmitting electrical power in residential, commercial, and light industrial settings.
Constructed with high-quality aluminium conductors, RBICAB LT Cables offer significant savings in material and installation costs compared to copper, while maintaining compliance with all necessary electrical performance standards. They are available in various configurations, including single-core and multi-core designs, to suit different circuit requirements.
These cables are ideal for final sub-circuit wiring, building power distribution, feeder lines to machinery, lighting systems, and internal electrical networks. Their design ensures minimal power loss, good short-circuit withstand capability, and reliable operation under normal low-tension load conditions.
Produced in accordance with IS, IEC, and BS standards, RBICAB LT Aluminium Cables guarantee safety, durability, and consistent performance. They are a smart choice for engineers and contractors looking to optimize project budgets without compromising on the quality and safety of electrical installations.
Feature / Application | Details |
|---|---|
Conductor Material | High-purity aluminium for lightweight, excellent conductivity, and efficient power transmission |
Cable Type | Armoured for mechanical protection (galvanized steel or aluminium) or unarmoured for indoor flexibility |
Insulation Material | PVC, XLPE, or other high-performance compounds resistant to heat, moisture, chemicals, and fire |
Primary Uses | Power distribution, industrial plants, renewable energy systems, commercial complexes, and infrastructure projects |
Mechanical Protection | Armoured cables protect against mechanical stress, impact, rodent attacks, and harsh environmental conditions |
Installation Environment | Indoor wiring, cable trays, panels, overhead installations, and outdoor underground deployments |
Durability | High mechanical strength, corrosion resistance, and long service life |
Standards Compliance | Manufactured as per IEC, IS, BS, and other international standards |
Performance | Ensures safe, efficient, and reliable power transmission with minimal energy loss |
Nominal Size of Conductor | Form of Conductor Circular | Nominal Thickness of XLPE Insulation For U/A | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Nominal Thickness of XLPE Insulation For Armoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating (Amps) | Normal Delivery Length (mtrs) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of Aluminium Round Wire | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||||
mm | mm | mm | mm | mm | Kgs./Km | mm | mm | mm | mm | Kgs./Km | mm | mm | mm | Kgs./Km | Amps. | Amps. | Mtrs. | |
4 | Solid | 0.70 | -NA- | 1.80 | 7.50 | 60 | - | - | - | - | - | - | - | - | - | 43 | 38 | 1000 |
4 | Stranded | 0.70 | -NA- | 1.80 | 8 | 65 | - | - | - | - | - | - | - | - | - | 43 | 38 | 1000 |
6 | Solid | 0.70 | -NA- | 1.80 | 8 | 70 | - | - | - | - | - | - | - | - | - | 55 | 50 | 1000 |
6 | Standard | 0.70 | -NA- | 1.80 | 8.50 | 75 | - | - | - | - | - | - | - | - | - | 55 | 50 | 1000 |
10 | Solid | 0.70 | -NA- | 1.80 | 9 | 80 | 1 | - | - | - | - | - | - | - | - | 69 | 64 | 1000 |
10 | Standard | 0.70 | -NA- | 1.80 | 9.50 | 90 | 1 | - | - | - | - | - | - | - | - | 69 | 64 | 1000 |
16 | Standard | 0.70 | -NA- | 1.80 | 10 | 115 | 1 | - | - | - | - | 1.40 | 1.24 | 13 | 193.30 | 69 | 64 | 1000 |
25 | Standard | 0.90 | -NA- | 1.80 | 12 | 155 | 1.20 | - | - | - | - | 1.40 | 1.24 | 14 | 250 | 115 | 112 | 1000 |
35 | Standard | 0.90 | -NA- | 1.80 | 13 | 180 | 1.20 | - | - | - | - | 1.40 | 1.24 | 15 | 293.40 | 137 | 137 | 1000 |
50 | Stranded | 1 | -NA- | 1.80 | 14 | 240 | 1.30 | - | - | - | - | 1.40 | 1.24 | 17 | 353.5 | 161 | 165 | 1000 |
70 | Stranded | 1.10 | -NA- | 1.80 | 16 | 310 | 1.40 | - | - | - | - | 1.40 | 1.24 | 19 | 443 | 198 | 209 | 1000 |
95 | Stranded | 1.10 | -NA- | 1.80 | 17.50 | 385 | 1.40 | 4x0.80 | 1.40 | 18.60 | 498.81 | 1.60 | 1.40 | 20.20 | 572.30 | 243 | 264 | 1000 |
120 | Stranded | 1.20 | -NA- | 1.80 | 19 | 470 | 1.50 | 4x0.80 | 1.40 | 20.40 | 606.34 | 1.60 | 1.40 | 23.50 | 678.74 | 276 | 308 | 1000 |
150 | Stranded | 1.40 | -NA- | 2 | 21.50 | 600 | 1.70 | 4x0.80 | 1.40 | 23 | 716.08 | 1.60 | 1.40 | 24.50 | 795.36 | 308 | 350 | 1000 |
185 | Stranded | 1.60 | -NA- | 2 | 23.50 | 710 | 1.90 | 4x0.80 | 1.40 | 25 | 866.86 | 1.60 | 1.40 | 26.50 | 947.06 | 349 | 406 | 1000 |
240 | Stranded | 1.70 | -NA- | 2 | 26 | 900 | 2 | 4x0.80 | 1.40 | 26.60 | 1055.79 | 1.60 | 1.40 | 29 | 1147.15 | 404 | 480 | 1000 |
300 | Stranded | 1.80 | -NA- | 2 | 28.50 | 1158 | 2.10 | 4x0.80 | 1.56 | 29.60 | 1294.16 | 1.60 | 1.56 | 31.50 | 1389.30 | 454 | 451 | 1000 |
400 | Stranded | 2 | -NA- | 2.20 | 33 | 1385 | 2.40 | 4x0.80 | 1.56 | 33.20 | 1624.42 | 2 | 1.56 | 36.50 | 1813.29 | 518 | 647 | 500 |
500 | Stranded | 2.20 | -NA- | 2.20 | 36 | 1650 | 2.60 | 4x0.80 | 1.56 | 36.70 | 1997.06 | 2 | 1.56 | 39.50 | 2213.57 | 588 | 751 | 500 |
630 | Stranded | 2.40 | -NA- | 2.20 | 40 | 2100 | 2.80 | 4x0.80 | 1.72 | 40.50 | 2469.72 | 2 | 1.72 | 43 | 2698.20 | 663 | 868 | 500 |
800 | Stranded | 2.60 | -NA- | 2.40 | 43.70 | 2730 | 3.10 | 4x0.80 | 1.72 | 46.50 | 2986.96 | 2 | 1.88 | 47.90 | 3279.82 | 740 | 992 | 550 |
1000 | Stranded | 2.80 | -NA- | 2.60 | 49.20 | 3350 | 3.30 | 4x0.80 | 1.88 | 50.60 | 3742.01 | 2.50 | 2.04 | 54.37 | 4220.31 | 812 | 1117 | 500 |
Nominal Size of Cable | 3, 3.5 & 4 Core PVC Insulated & Sheathed Cables | 3, 3.5 & 4 Core XLPE Insulated & Sheathed Cables | ||||
|---|---|---|---|---|---|---|
In Ground | In Air | Approx Voltage Drop | In Ground | In Air | Approx Voltage Drop | |
Amp | Amp | Mv/amp/mtr | Amp | Amp | Mv/amv/mtr | |
16 | 61 | 52 | 4.00 | 74 | 69 | 4.20 |
25 | 78 | 70 | 2.50 | 94 | 93 | 2.70 |
35 | 94 | 85 | 1.80 | 114 | 114 | 1.90 |
50 | 111 | 104 | 1.30 | 134 | 175 | 1.40 |
70 | 136 | 131 | 1.00 | 167 | 175 | 0.99 |
95 | 163 | 156 | 0.68 | 197 | 216 | 0.72 |
120 | 185 | 186 | 0.54 | 223 | 249 | 0.58 |
150 | 206 | 212 | 0.43 | 249 | 284 | 0.48 |
185 | 234 | 245 | 0.38 | 282 | 329 | 0.41 |
240 | 271 | 291 | 0.28 | 327 | 392 | 0.31 |
300 | 305 | 335 | 0.25 | 369 | 452 | 0.29 |
400 | 348 | 390 | 0.20 | 420 | 526 | 0.21 |
Nominal Size of Conductor | Minimum no. of wires | Max D.C. Resistance at 20°C | A.C. Resistance at 90°C | |||||
|---|---|---|---|---|---|---|---|---|
Non Compacted | Compacted | Plain Copper | Aluminium | Plain Copper | Aluminium | |||
Round/Shaped | ||||||||
CU. | ALU. | CU. | ALU. | Ohm/Km | Ohm/Km | Ohm/Km | Ohm/Km | |
1.5* | 3 | 3 | - | - | 12.10 | 18.1 | 15.50 | 23.17 |
2.5* | 3 | 3 | - | - | 7.41 | 12.1 | 9.48 | 15.50 |
4* | 7 | 3 | - | - | 4.61 | 7.41 | 5.90 | 9.48 |
6* | 7 | 3 | - | - | 3.08 | 4.61 | 3.94 | 5.90 |
10* | 7 | 7 | 6 | - | 1.83 | 3.08 | 2.34 | 3.94 |
16 | 7 | 7 | 6 | 6 | 1.15 | 1.91 | 1.47 | 2.44 |
25 | 7 | 7 | 6 | 6 | 0.727 | 1.20 | 0.93 | 1.54 |
35 | 7 | 7 | 6 | 6 | 0.524 | 0.868 | 0.671 | 1.11 |
50 | 19 | 19 | 6 | 6 | 0.387 | 0.641 | 0.495 | 0.82 |
70 | 19 | 19 | 12 | 12 | 0.268 | 0.443 | 0.343 | 0.567 |
95 | 19 | 19 | 15 | 15 | 0.193 | 0.32 | 0.247 | 0.410 |
120 | 37 | 37 | 18 | 15 | 0.153 | 0.253 | 0.196 | 0.324 |
150 | 37 | 37 | 18 | 15 | 0.124 | 0.206 | 0.159 | 0.264 |
185 | 37 | 37 | 30 | 30 | 0.0991 | 0.164 | 0.127 | 0.210 |
240 | 61 | 37 | 34 | 30 | 0.0754 | 0.125 | 0.0965 | 0.160 |
300 | 61 | 61 | 34 | 30 | 0.0601 | 0.100 | 0.0769 | 0.128 |
400 | 61 | 61 | 53 | 53 | 0.047 | 0.0778 | 0.0602 | 0.100 |
500 | 61 | 61 | 53 | 53 | 0.0366 | 0.0605 | 0.0468 | 0.0774 |
630 | 91 | 91 | 53 | 53 | 0.0283 | 0.0469 | 0.0362 | 0.0600 |
800 | 91 | 91 | 53 | 53 | 0.0221 | 0.0367 | 0.0283 | 0.0470 |
Nominal Size of Conductor | Form of Conductor Circular Shaped O/Q | Nominal Thickness of XLPE Insulation For U/A | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of Aluminium Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of Aluminium Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 12.50 | 140 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 14.50 | 400 | 42 | 38 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 13 | 150 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.50 | 430 | 42 | 38 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 13.50 | 170 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.50 | 470 | 55 | 50 | 1000 |
6 | Stranded o | 0.70 | 0.30 | 1.80 | 14 | 180 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16.50 | 485 | 55 | 50 | 1000 |
10 | Solid o | 0.70 | 0.30 | 1.80 | 15 | 205 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17 | 545 | 68 | 64 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 16 | 225 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18 | 565 | 68 | 64 | 1000 |
16 | Stranded Q | 0.70 | 0.30 | 1.80 | 14 | 225 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.20 | 17 | 480.16 | 89 | 83 | 1000 |
25 | Stranded Q | 0.90 | 0.30 | 2 | 17 | 330 | 4x0.80 | 1.40 | 18.50 | 509.13 | 1.60 | 1.40 | 20 | 671.84 | 114 | 109 | 1000 |
35 | Stranded Q | 0.90 | 0.30 | 2 | 19 | 410 | 4x0.80 | 1.40 | 20 | 605.51 | 1.60 | 1.40 | 22 | 775.55 | 136 | 133 | 1000 |
50 | Stranded Q | 1 | 0.30 | 2 | 21 | 510 | 4x0.80 | 1.40 | 22.50 | 753.28 | 1.60 | 1.40 | 24 | 937.97 | 161 | 162 | 1000 |
70 | Stranded Q | 1.10 | 0.30 | 2 | 23 | 675 | 4x0.80 | 1.56 | 22.50 | 971 | 1.60 | 1.56 | 27 | 1188.85 | 197 | 204 | 1000 |
95 | Stranded Q | 1.10 | 0.40 | 2.20 | 26.50 | 900 | 4x0.80 | 1.56 | 28 | 1204.30 | 2 | 1.56 | 28.68 | 1572.78 | 235 | 251 | 1000 |
120 | Stranded Q | 1.20 | 0.40 | 2.20 | 28.50 | 1050 | 4x0.80 | 1.56 | 30.50 | 1408.20 | 2 | 1.56 | 33 | 1849.49 | 266 | 287 | 500 |
150 | Stranded Q | 1.40 | 0.40 | 2.20 | 32 | 1215 | 4x0.80 | 1.72 | 31.79 | 1690.20 | 2 | 1.72 | 36 | 2182.96 | 296 | 328 | 500 |
185 | Stranded Q | 1.60 | 0.50 | 2.40 | 35.50 | 1510 | 4x0.80 | 1.72 | 34.95 | 2025.90 | 2 | 1.88 | 37.70 | 2597.60 | 335 | 379 | 500 |
240 | Stranded Q | 1.70 | 0.50 | 2.60 | 39.50 | 1900 | 4x0.80 | 1.88 | 38.69 | 2500.60 | 2.50 | 2.04 | 45 | 3418.52 | 385 | 448 | 500 |
300 | Stranded Q | 1.80 | 0.60 | 2.80 | 43.50 | 2360 | 4x0.80 | 2.04 | 42.53 | 2992.20 | 2.50 | 2.20 | 46.22 | 4019.07 | 432 | 513 | 500 |
400 | Stranded Q | 2 | 0.60 | 3 | 49 | 3100 | 4x0.80 | 2.36 | 48.24 | 3790.21 | 2.50 | 2.36 | 51.61 | 4880.51 | 487 | 593 | 500 |
500 | Stranded Q | 2.20 | 0.70 | 3.40 | 55.50 | 4000 | 4x0.80 | 2.52 | 56.50 | 5000 | 3.15 | 2.68 | 61.50 | 7000 | 548 | 683 | 500 |
630 | Stranded | 2.40 | 0.70 | 3.60 | 61.50 | 5000 | 4x0.80 | 2.68 | 62.50 | 6050 | 3.15 | 2.84 | 67.50 | 8560 | 612 | 784 | 500 |
Nominal Size of Conductor | Form of Conductor Circular Shaped O/zs | Nominal Thickness of XLPE Insulation | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 14 | 140 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15 | 460 | 35 | 32 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 15.50 | 160 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 510 | 35 | 32 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 15.50 | 170 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 530 | 46 | 42 | 1000 |
6 | Stranded ^ | 0.70 | 0.30 | 1.80 | 16 | 190 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17 | 580 | 46 | 42 | 1000 |
10 | Solid ^ | 0.70 | 0.30 | 1.80 | 17 | 220 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18 | 640 | 57 | 54 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 18 | 230 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18.50 | 680 | 57 | 54 | 1000 |
16 | Stranded ^ | 0.70 | 0.30 | 1.80 | 16.20 | 310 | 4x0.80 | 1.24 | 16.80 | 487.60 | 1.60 | 1.40 | 19 | 648.40 | 74 | 69 | 1000 |
25 | Stranded ^ | 0.90 | 0.30 | 2 | 19.50 | 460 | 4x0.80 | 1.40 | 20.10 | 670.70 | 1.60 | 1.40 | 21.70 | 863.30 | 95 | 93 | 1000 |
35 | Stranded ^ | 0.90 | 0.30 | 2 | 21.50 | 573.80 | 4x0.80 | 1.40 | 22 | 800.60 | 1.60 | 1.40 | 23.60 | 1015.80 | 114 | 114 | 1000 |
50 | Stranded ^ | 1 | 0.30 | 2 | 24.50 | 700 | 4x0.80 | 1.40 | 24.80 | 993.7 | 1.60 | 1.56 | 26.80 | 1259.60 | 134 | 138 | 1000 |
70 | Stranded ^ | 1.10 | 0.40 | 2.20 | 28 | 990 | 4x0.80 | 1.56 | 28.50 | 1299.60 | 2 | 1.56 | 30.90 | 1740.10 | 164 | 175 | 500 |
95 | Stranded ^ | 1.10 | 0.40 | 2.20 | 30.80 | 1250 | 4x0.80 | 1.56 | 31.30 | 1603 | 2 | 1.56 | 33.70 | 2117 | 197 | 216 | 500 |
120 | Stranded ^ | 1.20 | 0.40 | 2.20 | 33.80 | 1525 | 4x0.80 | 1.56 | 34.30 | 1914.10 | 2 | 1.72 | 37 | 2506.50 | 223 | 249 | 500 |
150 | Stranded ^ | 1.40 | 0.50 | 2.40 | 37.90 | 1895.90 | 4x0.80 | 1.72 | 38.30 | 2100 | 2 | 1.88 | 41.10 | 2988.80 | 249 | 284 | 500 |
185 | Stranded ^ | 1.60 | 0.50 | 2.60 | 42 | 2349.30 | 4x0.80 | 1.88 | 42.30 | 2500 | 2.50 | 2.04 | 46 | 3867.40 | 282 | 329 | 500 |
240 | Stranded ^ | 1.70 | 0.60 | 2.80 | 46.90 | 2981.40 | 4x0.80 | 2.04 | 47.20 | 3459.80 | 2.50 | 2.20 | 50.90 | 4677.30 | 327 | 392 | 500 |
300 | Stranded ^ | 1.80 | 0.60 | 3 | 51.50 | 3615.80 | 4x0.80 | 2.20 | 51.80 | 4150.20 | 2.50 | 2.36 | 55.45 | 5491.40 | 369 | 452 | 500 |
400 | Stranded ^ | 2 | 0.70 | 3.20 | 58.60 | 4650.10 | 4x0.80 | 2.52 | 58.50 | 5250.60 | 3.15 | 2.68 | 64 | 7401.40 | 420 | 526 | 500 |
500 | Stranded ^ | 2.20 | 0.70 | 3.60 | 66 | 6000 | 4x0.80 | 2.68 | 67 | 6900 | 3.15 | 2.84 | 73 | 9550 | 478 | 612 | 250 |
630 | Stranded ^ | 2.40 | 0.70 | 3.80 | 72 | 7550 | 4x0.80 | 2.84 | 73 | 8700 | 4 | 3 | 78 | 12500 | 542 | 712 | 250 |
Nominal Size of Conductor | Form of Conductor Circular Shaped | Nominal Thickness of XLPE Insulation Main / Neutral | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | ||||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | ||
25/16 | Stranded | 0.90 | 0.70 | 0.30 | 2 | 21.30 | 525 | 4×0.80 | 1.40 | 21.90 | 733 | 1.60 | 1.40 | 23.60 | 971 | 95 | 93 | 1000 |
35/16 | Stranded | 0.90 | 0.70 | 0.30 | 2 | 23.60 | 625 | 4×0.80 | 1.40 | 24.20 | 886 | 1.60 | 1.40 | 25.80 | 1139 | 114 | 114 | 1000 |
50/25 | Stranded | 1 | 0.90 | 0.40 | 2 | 26.80 | 800 | 4×0.80 | 1.40 | 27.40 | 1113 | 1.60 | 1.56 | 29.50 | 1419 | 134 | 138 | 1000 |
70/35 | Stranded | 1.10 | 0.90 | 0.40 | 2.20 | 31 | 1100 | 4×0.80 | 1.56 | 31.50 | 1451 | 2 | 1.56 | 34 | 1989 | 164 | 175 | 500 |
95/50 | Stranded | 1.20 | 1.00 | 0.40 | 2.20 | 34.30 | 1400 | 4×0.80 | 1.56 | 34.80 | 1796 | 2 | 1.56 | 37.20 | 2382 | 197 | 216 | 500 |
120/70 | Stranded | 1.20 | 1.10 | 0.40 | 2.20 | 37.50 | 1650 | 4×0.80 | 1.72 | 38.50 | 2199 | 2 | 1.72 | 41 | 2800 | 223 | 249 | 500 |
150/70 | Stranded | 1.40 | 1.10 | 0.50 | 2.40 | 41 | 2000 | 4×0.80 | 1.72 | 42 | 2579 | 2 | 1.88 | 45 | 3350 | 249 | 282 | 500 |
185/95 | Stranded | 1.60 | 1.10 | 0.50 | 2.60 | 46.50 | 2550 | 4×0.80 | 1.88 | 47.20 | 3166 | 2.50 | 2.04 | 50 | 4381 | 282 | 329 | 500 |
240/120 | Stranded | 1.70 | 1.20 | 0.60 | 2.80 | 52.50 | 3200 | 4×0.80 | 2.04 | 52.70 | 3913 | 2.50 | 2.20 | 56 | 5313 | 327 | 392 | 500 |
300/150 | Stranded | 1.80 | 1.40 | 0.60 | 3 | 56 | 4000 | 4×0.80 | 2.20 | 57 | 4716 | 2.50 | 2.50 | 56 | 6254 | 369 | 452 | 250 |
400/185 | Stranded | 2 | 1.70 | 0.70 | 3.40 | 64 | 5250 | 4×0.80 | 2.52 | 65 | 6000 | 3.15 | 2.50 | 61 | 8300 | 420 | 526 | 500 |
500/240 | Stranded | 2.20 | 1.70 | 0.70 | 3.60 | 72.50 | 6500 | 4×0.80 | 2.68 | 73.50 | 7400 | 3.15 | 2.84 | 77 | 9880 | 478 | 612 | 250 |
Nominal Size of Conductor | Form of Conductor Circular Shaped | Nominal Thickness of XLPE Insulation | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 13.50 | 160 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.30 | 413 | 35 | 32 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 14.20 | 180 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 435 | 35 | 32 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 14.70 | 200 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16.50 | 473 | 46 | 42 | 1000 |
6 | Stranded o | 0.70 | 0.30 | 1.80 | 15.50 | 215 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17.30 | 506 | 46 | 42 | 1000 |
10 | Solid o | 0.70 | 0.30 | 1.80 | 16.60 | 250 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.40 | 18.60 | 592 | 57 | 54 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 17.50 | 260 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.40 | 19.80 | 633 | 57 | 54 | 1000 |
16 | Stranded | 0.70 | 0.30 | 1.80 | 17.80 | 350 | 4*0.80 | 1.40 | 20 | 624.50 | 1.60 | 1.40 | 21 | 795 | 74 | 69 | 1000 |
25 | Stranded | 0.90 | 0.30 | 2 | 21 | 550 | 4*0.80 | 1.40 | 23 | 828.50 | 1.60 | 1.40 | 25 | 1062 | 95 | 93 | 500 |
35 | Stranded | 0.90 | 0.30 | 2 | 23.50 | 680 | 4*0.80 | 1.40 | 25 | 1015.50 | 1.60 | 1.40 | 26.50 | 1259 | 114 | 114 | 500 |
50 | Stranded | 1 | 0.30 | 2 | 26 | 875 | 4*0.80 | 1.56 | 28 | 1275 | 1.60 | 1.56 | 29.50 | 1581 | 134 | 138 | 500 |
70 | Stranded | 1.10 | 0.40 | 2.20 | 30.50 | 1200 | 4*0.80 | 1.56 | 32 | 1656.40 | 2 | 1.56 | 34 | 2175 | 164 | 175 | 500 |
95 | Stranded | 1.10 | 0.40 | 2.20 | 33.50 | 1530 | 4*0.80 | 1.56 | 35 | 2041.90 | 2 | 1.72 | 38 | 2695 | 197 | 216 | 500 |
120 | Stranded | 1.20 | 0.50 | 2.40 | 37.50 | 1850 | 4*0.80 | 1.72 | 39 | 2442.50 | 2 | 1.88 | 42 | 3241 | 223 | 249 | 500 |
150 | Stranded | 1.40 | 0.50 | 2.60 | 42 | 2280 | 4*0.80 | 1.88 | 43 | 2929.90 | 2.50 | 2.04 | 47 | 4167 | 249 | 284 | 500 |
185 | Stranded | 1.60 | 0.50 | 2.80 | 46.50 | 2800 | 4*0.80 | 2.04 | 48 | 3563.10 | 2.50 | 2.20 | 52 | 4928 | 282 | 329 | 500 |
240 | Stranded | 1.70 | 0.60 | 3 | 52.50 | 3700 | 4*0.80 | 2.20 | 54 | 4464.30 | 2.50 | 2.36 | 57.50 | 5998 | 327 | 292 | 500 |
300 | Stranded | 1.80 | 0.70 | 3.20 | 58 | 4600 | 4*0.80 | 2.36 | 59.50 | 5359.50 | 3.15 | 2.52 | 64.50 | 7722 | 369 | 452 | 500 |
400 | Stranded | 2 | 0.70 | 3.60 | 65.50 | 6000 | 4*0.80 | 2.68 | 66.50 | 6749.30 | 3.15 | 2.84 | 71.50 | 9487 | 420 | 526 | 500 |
D-18, Site-3, Meerut Road Industrial Area, UPSIDC, Ghaziabad, Uttar Pradesh 201003 (INDIA)