As one of the leading manufacturers of Domestic & Industrial Electric Wires and Cables in India, we have always believed in setting higher benchmarks of quality, safety, and reliability.
RBICAB Industrial Aluminium Electrical Cables are heavy-duty cables engineered to meet the rigorous demands of industrial environments. These cables combine the economic and lightweight benefits of aluminium with robust construction to ensure reliable power supply in factories, plants, mills, and processing units.
Built to withstand harsh industrial conditions such as high temperatures, moisture, oils, chemicals, and constant vibration, these cables feature enhanced insulation and, when required, mechanical armour protection. They are designed for high current-carrying capacity, excellent thermal stability, and long service life under continuous operational stress.
Common applications include powering heavy machinery, motor feeder circuits, control panels, assembly lines, crane systems, and outdoor industrial lighting. The aluminium construction reduces overall weight on cable trays and supports, easing installation and structural load.
Fully compliant with industrial standards like IEC, IS, and BS, RBICAB Industrial Aluminium Cables prioritize safety with features like flame retardancy, low smoke emission, and high short-circuit ratings. They are the preferred wiring solution for industrial projects demanding durability, cost efficiency, and uncompromised electrical performance.
Feature / Application | Details |
|---|---|
Conductor Material | High-purity aluminium for lightweight, excellent conductivity, and efficient power transmission |
Cable Type | Armoured for mechanical protection (galvanized steel or aluminium) or unarmoured for indoor flexibility |
Insulation Material | PVC, XLPE, or other high-performance compounds resistant to heat, moisture, chemicals, and fire |
Primary Uses | Power distribution, industrial plants, renewable energy systems, commercial complexes, and infrastructure projects |
Mechanical Protection | Armoured cables protect against mechanical stress, impact, rodent attacks, and harsh environmental conditions |
Installation Environment | Indoor wiring, cable trays, panels, overhead installations, and outdoor underground deployments |
Durability | High mechanical strength, corrosion resistance, and long service life |
Standards Compliance | Manufactured as per IEC, IS, BS, and other international standards |
Performance | Ensures safe, efficient, and reliable power transmission with minimal energy loss |
Nominal Size of Conductor | Form of Conductor Circular | Nominal Thickness of XLPE Insulation For U/A | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Nominal Thickness of XLPE Insulation For Armoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating (Amps) | Normal Delivery Length (mtrs) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of Aluminium Round Wire | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||||
mm | mm | mm | mm | mm | Kgs./Km | mm | mm | mm | mm | Kgs./Km | mm | mm | mm | Kgs./Km | Amps. | Amps. | Mtrs. | |
4 | Solid | 0.70 | -NA- | 1.80 | 7.50 | 60 | - | - | - | - | - | - | - | - | - | 43 | 38 | 1000 |
4 | Stranded | 0.70 | -NA- | 1.80 | 8 | 65 | - | - | - | - | - | - | - | - | - | 43 | 38 | 1000 |
6 | Solid | 0.70 | -NA- | 1.80 | 8 | 70 | - | - | - | - | - | - | - | - | - | 55 | 50 | 1000 |
6 | Standard | 0.70 | -NA- | 1.80 | 8.50 | 75 | - | - | - | - | - | - | - | - | - | 55 | 50 | 1000 |
10 | Solid | 0.70 | -NA- | 1.80 | 9 | 80 | 1 | - | - | - | - | - | - | - | - | 69 | 64 | 1000 |
10 | Standard | 0.70 | -NA- | 1.80 | 9.50 | 90 | 1 | - | - | - | - | - | - | - | - | 69 | 64 | 1000 |
16 | Standard | 0.70 | -NA- | 1.80 | 10 | 115 | 1 | - | - | - | - | 1.40 | 1.24 | 13 | 193.30 | 69 | 64 | 1000 |
25 | Standard | 0.90 | -NA- | 1.80 | 12 | 155 | 1.20 | - | - | - | - | 1.40 | 1.24 | 14 | 250 | 115 | 112 | 1000 |
35 | Standard | 0.90 | -NA- | 1.80 | 13 | 180 | 1.20 | - | - | - | - | 1.40 | 1.24 | 15 | 293.40 | 137 | 137 | 1000 |
50 | Stranded | 1 | -NA- | 1.80 | 14 | 240 | 1.30 | - | - | - | - | 1.40 | 1.24 | 17 | 353.5 | 161 | 165 | 1000 |
70 | Stranded | 1.10 | -NA- | 1.80 | 16 | 310 | 1.40 | - | - | - | - | 1.40 | 1.24 | 19 | 443 | 198 | 209 | 1000 |
95 | Stranded | 1.10 | -NA- | 1.80 | 17.50 | 385 | 1.40 | 4x0.80 | 1.40 | 18.60 | 498.81 | 1.60 | 1.40 | 20.20 | 572.30 | 243 | 264 | 1000 |
120 | Stranded | 1.20 | -NA- | 1.80 | 19 | 470 | 1.50 | 4x0.80 | 1.40 | 20.40 | 606.34 | 1.60 | 1.40 | 23.50 | 678.74 | 276 | 308 | 1000 |
150 | Stranded | 1.40 | -NA- | 2 | 21.50 | 600 | 1.70 | 4x0.80 | 1.40 | 23 | 716.08 | 1.60 | 1.40 | 24.50 | 795.36 | 308 | 350 | 1000 |
185 | Stranded | 1.60 | -NA- | 2 | 23.50 | 710 | 1.90 | 4x0.80 | 1.40 | 25 | 866.86 | 1.60 | 1.40 | 26.50 | 947.06 | 349 | 406 | 1000 |
240 | Stranded | 1.70 | -NA- | 2 | 26 | 900 | 2 | 4x0.80 | 1.40 | 26.60 | 1055.79 | 1.60 | 1.40 | 29 | 1147.15 | 404 | 480 | 1000 |
300 | Stranded | 1.80 | -NA- | 2 | 28.50 | 1158 | 2.10 | 4x0.80 | 1.56 | 29.60 | 1294.16 | 1.60 | 1.56 | 31.50 | 1389.30 | 454 | 451 | 1000 |
400 | Stranded | 2 | -NA- | 2.20 | 33 | 1385 | 2.40 | 4x0.80 | 1.56 | 33.20 | 1624.42 | 2 | 1.56 | 36.50 | 1813.29 | 518 | 647 | 500 |
500 | Stranded | 2.20 | -NA- | 2.20 | 36 | 1650 | 2.60 | 4x0.80 | 1.56 | 36.70 | 1997.06 | 2 | 1.56 | 39.50 | 2213.57 | 588 | 751 | 500 |
630 | Stranded | 2.40 | -NA- | 2.20 | 40 | 2100 | 2.80 | 4x0.80 | 1.72 | 40.50 | 2469.72 | 2 | 1.72 | 43 | 2698.20 | 663 | 868 | 500 |
800 | Stranded | 2.60 | -NA- | 2.40 | 43.70 | 2730 | 3.10 | 4x0.80 | 1.72 | 46.50 | 2986.96 | 2 | 1.88 | 47.90 | 3279.82 | 740 | 992 | 550 |
1000 | Stranded | 2.80 | -NA- | 2.60 | 49.20 | 3350 | 3.30 | 4x0.80 | 1.88 | 50.60 | 3742.01 | 2.50 | 2.04 | 54.37 | 4220.31 | 812 | 1117 | 500 |
Nominal Size of Cable | 3, 3.5 & 4 Core PVC Insulated & Sheathed Cables | 3, 3.5 & 4 Core XLPE Insulated & Sheathed Cables | ||||
|---|---|---|---|---|---|---|
In Ground | In Air | Approx Voltage Drop | In Ground | In Air | Approx Voltage Drop | |
Amp | Amp | Mv/amp/mtr | Amp | Amp | Mv/amv/mtr | |
16 | 61 | 52 | 4.00 | 74 | 69 | 4.20 |
25 | 78 | 70 | 2.50 | 94 | 93 | 2.70 |
35 | 94 | 85 | 1.80 | 114 | 114 | 1.90 |
50 | 111 | 104 | 1.30 | 134 | 175 | 1.40 |
70 | 136 | 131 | 1.00 | 167 | 175 | 0.99 |
95 | 163 | 156 | 0.68 | 197 | 216 | 0.72 |
120 | 185 | 186 | 0.54 | 223 | 249 | 0.58 |
150 | 206 | 212 | 0.43 | 249 | 284 | 0.48 |
185 | 234 | 245 | 0.38 | 282 | 329 | 0.41 |
240 | 271 | 291 | 0.28 | 327 | 392 | 0.31 |
300 | 305 | 335 | 0.25 | 369 | 452 | 0.29 |
400 | 348 | 390 | 0.20 | 420 | 526 | 0.21 |
Nominal Size of Conductor | Minimum no. of wires | Max D.C. Resistance at 20°C | A.C. Resistance at 90°C | |||||
|---|---|---|---|---|---|---|---|---|
Non Compacted | Compacted | Plain Copper | Aluminium | Plain Copper | Aluminium | |||
Round/Shaped | ||||||||
CU. | ALU. | CU. | ALU. | Ohm/Km | Ohm/Km | Ohm/Km | Ohm/Km | |
1.5* | 3 | 3 | - | - | 12.10 | 18.1 | 15.50 | 23.17 |
2.5* | 3 | 3 | - | - | 7.41 | 12.1 | 9.48 | 15.50 |
4* | 7 | 3 | - | - | 4.61 | 7.41 | 5.90 | 9.48 |
6* | 7 | 3 | - | - | 3.08 | 4.61 | 3.94 | 5.90 |
10* | 7 | 7 | 6 | - | 1.83 | 3.08 | 2.34 | 3.94 |
16 | 7 | 7 | 6 | 6 | 1.15 | 1.91 | 1.47 | 2.44 |
25 | 7 | 7 | 6 | 6 | 0.727 | 1.20 | 0.93 | 1.54 |
35 | 7 | 7 | 6 | 6 | 0.524 | 0.868 | 0.671 | 1.11 |
50 | 19 | 19 | 6 | 6 | 0.387 | 0.641 | 0.495 | 0.82 |
70 | 19 | 19 | 12 | 12 | 0.268 | 0.443 | 0.343 | 0.567 |
95 | 19 | 19 | 15 | 15 | 0.193 | 0.32 | 0.247 | 0.410 |
120 | 37 | 37 | 18 | 15 | 0.153 | 0.253 | 0.196 | 0.324 |
150 | 37 | 37 | 18 | 15 | 0.124 | 0.206 | 0.159 | 0.264 |
185 | 37 | 37 | 30 | 30 | 0.0991 | 0.164 | 0.127 | 0.210 |
240 | 61 | 37 | 34 | 30 | 0.0754 | 0.125 | 0.0965 | 0.160 |
300 | 61 | 61 | 34 | 30 | 0.0601 | 0.100 | 0.0769 | 0.128 |
400 | 61 | 61 | 53 | 53 | 0.047 | 0.0778 | 0.0602 | 0.100 |
500 | 61 | 61 | 53 | 53 | 0.0366 | 0.0605 | 0.0468 | 0.0774 |
630 | 91 | 91 | 53 | 53 | 0.0283 | 0.0469 | 0.0362 | 0.0600 |
800 | 91 | 91 | 53 | 53 | 0.0221 | 0.0367 | 0.0283 | 0.0470 |
Nominal Size of Conductor | Form of Conductor Circular Shaped O/Q | Nominal Thickness of XLPE Insulation For U/A | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of Aluminium Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of Aluminium Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 12.50 | 140 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 14.50 | 400 | 42 | 38 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 13 | 150 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.50 | 430 | 42 | 38 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 13.50 | 170 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.50 | 470 | 55 | 50 | 1000 |
6 | Stranded o | 0.70 | 0.30 | 1.80 | 14 | 180 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16.50 | 485 | 55 | 50 | 1000 |
10 | Solid o | 0.70 | 0.30 | 1.80 | 15 | 205 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17 | 545 | 68 | 64 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 16 | 225 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18 | 565 | 68 | 64 | 1000 |
16 | Stranded Q | 0.70 | 0.30 | 1.80 | 14 | 225 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.20 | 17 | 480.16 | 89 | 83 | 1000 |
25 | Stranded Q | 0.90 | 0.30 | 2 | 17 | 330 | 4x0.80 | 1.40 | 18.50 | 509.13 | 1.60 | 1.40 | 20 | 671.84 | 114 | 109 | 1000 |
35 | Stranded Q | 0.90 | 0.30 | 2 | 19 | 410 | 4x0.80 | 1.40 | 20 | 605.51 | 1.60 | 1.40 | 22 | 775.55 | 136 | 133 | 1000 |
50 | Stranded Q | 1 | 0.30 | 2 | 21 | 510 | 4x0.80 | 1.40 | 22.50 | 753.28 | 1.60 | 1.40 | 24 | 937.97 | 161 | 162 | 1000 |
70 | Stranded Q | 1.10 | 0.30 | 2 | 23 | 675 | 4x0.80 | 1.56 | 22.50 | 971 | 1.60 | 1.56 | 27 | 1188.85 | 197 | 204 | 1000 |
95 | Stranded Q | 1.10 | 0.40 | 2.20 | 26.50 | 900 | 4x0.80 | 1.56 | 28 | 1204.30 | 2 | 1.56 | 28.68 | 1572.78 | 235 | 251 | 1000 |
120 | Stranded Q | 1.20 | 0.40 | 2.20 | 28.50 | 1050 | 4x0.80 | 1.56 | 30.50 | 1408.20 | 2 | 1.56 | 33 | 1849.49 | 266 | 287 | 500 |
150 | Stranded Q | 1.40 | 0.40 | 2.20 | 32 | 1215 | 4x0.80 | 1.72 | 31.79 | 1690.20 | 2 | 1.72 | 36 | 2182.96 | 296 | 328 | 500 |
185 | Stranded Q | 1.60 | 0.50 | 2.40 | 35.50 | 1510 | 4x0.80 | 1.72 | 34.95 | 2025.90 | 2 | 1.88 | 37.70 | 2597.60 | 335 | 379 | 500 |
240 | Stranded Q | 1.70 | 0.50 | 2.60 | 39.50 | 1900 | 4x0.80 | 1.88 | 38.69 | 2500.60 | 2.50 | 2.04 | 45 | 3418.52 | 385 | 448 | 500 |
300 | Stranded Q | 1.80 | 0.60 | 2.80 | 43.50 | 2360 | 4x0.80 | 2.04 | 42.53 | 2992.20 | 2.50 | 2.20 | 46.22 | 4019.07 | 432 | 513 | 500 |
400 | Stranded Q | 2 | 0.60 | 3 | 49 | 3100 | 4x0.80 | 2.36 | 48.24 | 3790.21 | 2.50 | 2.36 | 51.61 | 4880.51 | 487 | 593 | 500 |
500 | Stranded Q | 2.20 | 0.70 | 3.40 | 55.50 | 4000 | 4x0.80 | 2.52 | 56.50 | 5000 | 3.15 | 2.68 | 61.50 | 7000 | 548 | 683 | 500 |
630 | Stranded | 2.40 | 0.70 | 3.60 | 61.50 | 5000 | 4x0.80 | 2.68 | 62.50 | 6050 | 3.15 | 2.84 | 67.50 | 8560 | 612 | 784 | 500 |
Nominal Size of Conductor | Form of Conductor Circular Shaped O/zs | Nominal Thickness of XLPE Insulation | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 14 | 140 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15 | 460 | 35 | 32 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 15.50 | 160 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 510 | 35 | 32 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 15.50 | 170 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 530 | 46 | 42 | 1000 |
6 | Stranded ^ | 0.70 | 0.30 | 1.80 | 16 | 190 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17 | 580 | 46 | 42 | 1000 |
10 | Solid ^ | 0.70 | 0.30 | 1.80 | 17 | 220 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18 | 640 | 57 | 54 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 18 | 230 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18.50 | 680 | 57 | 54 | 1000 |
16 | Stranded ^ | 0.70 | 0.30 | 1.80 | 16.20 | 310 | 4x0.80 | 1.24 | 16.80 | 487.60 | 1.60 | 1.40 | 19 | 648.40 | 74 | 69 | 1000 |
25 | Stranded ^ | 0.90 | 0.30 | 2 | 19.50 | 460 | 4x0.80 | 1.40 | 20.10 | 670.70 | 1.60 | 1.40 | 21.70 | 863.30 | 95 | 93 | 1000 |
35 | Stranded ^ | 0.90 | 0.30 | 2 | 21.50 | 573.80 | 4x0.80 | 1.40 | 22 | 800.60 | 1.60 | 1.40 | 23.60 | 1015.80 | 114 | 114 | 1000 |
50 | Stranded ^ | 1 | 0.30 | 2 | 24.50 | 700 | 4x0.80 | 1.40 | 24.80 | 993.7 | 1.60 | 1.56 | 26.80 | 1259.60 | 134 | 138 | 1000 |
70 | Stranded ^ | 1.10 | 0.40 | 2.20 | 28 | 990 | 4x0.80 | 1.56 | 28.50 | 1299.60 | 2 | 1.56 | 30.90 | 1740.10 | 164 | 175 | 500 |
95 | Stranded ^ | 1.10 | 0.40 | 2.20 | 30.80 | 1250 | 4x0.80 | 1.56 | 31.30 | 1603 | 2 | 1.56 | 33.70 | 2117 | 197 | 216 | 500 |
120 | Stranded ^ | 1.20 | 0.40 | 2.20 | 33.80 | 1525 | 4x0.80 | 1.56 | 34.30 | 1914.10 | 2 | 1.72 | 37 | 2506.50 | 223 | 249 | 500 |
150 | Stranded ^ | 1.40 | 0.50 | 2.40 | 37.90 | 1895.90 | 4x0.80 | 1.72 | 38.30 | 2100 | 2 | 1.88 | 41.10 | 2988.80 | 249 | 284 | 500 |
185 | Stranded ^ | 1.60 | 0.50 | 2.60 | 42 | 2349.30 | 4x0.80 | 1.88 | 42.30 | 2500 | 2.50 | 2.04 | 46 | 3867.40 | 282 | 329 | 500 |
240 | Stranded ^ | 1.70 | 0.60 | 2.80 | 46.90 | 2981.40 | 4x0.80 | 2.04 | 47.20 | 3459.80 | 2.50 | 2.20 | 50.90 | 4677.30 | 327 | 392 | 500 |
300 | Stranded ^ | 1.80 | 0.60 | 3 | 51.50 | 3615.80 | 4x0.80 | 2.20 | 51.80 | 4150.20 | 2.50 | 2.36 | 55.45 | 5491.40 | 369 | 452 | 500 |
400 | Stranded ^ | 2 | 0.70 | 3.20 | 58.60 | 4650.10 | 4x0.80 | 2.52 | 58.50 | 5250.60 | 3.15 | 2.68 | 64 | 7401.40 | 420 | 526 | 500 |
500 | Stranded ^ | 2.20 | 0.70 | 3.60 | 66 | 6000 | 4x0.80 | 2.68 | 67 | 6900 | 3.15 | 2.84 | 73 | 9550 | 478 | 612 | 250 |
630 | Stranded ^ | 2.40 | 0.70 | 3.80 | 72 | 7550 | 4x0.80 | 2.84 | 73 | 8700 | 4 | 3 | 78 | 12500 | 542 | 712 | 250 |
Nominal Size of Conductor | Form of Conductor Circular Shaped | Nominal Thickness of XLPE Insulation Main / Neutral | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | ||||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | ||
25/16 | Stranded | 0.90 | 0.70 | 0.30 | 2 | 21.30 | 525 | 4×0.80 | 1.40 | 21.90 | 733 | 1.60 | 1.40 | 23.60 | 971 | 95 | 93 | 1000 |
35/16 | Stranded | 0.90 | 0.70 | 0.30 | 2 | 23.60 | 625 | 4×0.80 | 1.40 | 24.20 | 886 | 1.60 | 1.40 | 25.80 | 1139 | 114 | 114 | 1000 |
50/25 | Stranded | 1 | 0.90 | 0.40 | 2 | 26.80 | 800 | 4×0.80 | 1.40 | 27.40 | 1113 | 1.60 | 1.56 | 29.50 | 1419 | 134 | 138 | 1000 |
70/35 | Stranded | 1.10 | 0.90 | 0.40 | 2.20 | 31 | 1100 | 4×0.80 | 1.56 | 31.50 | 1451 | 2 | 1.56 | 34 | 1989 | 164 | 175 | 500 |
95/50 | Stranded | 1.20 | 1.00 | 0.40 | 2.20 | 34.30 | 1400 | 4×0.80 | 1.56 | 34.80 | 1796 | 2 | 1.56 | 37.20 | 2382 | 197 | 216 | 500 |
120/70 | Stranded | 1.20 | 1.10 | 0.40 | 2.20 | 37.50 | 1650 | 4×0.80 | 1.72 | 38.50 | 2199 | 2 | 1.72 | 41 | 2800 | 223 | 249 | 500 |
150/70 | Stranded | 1.40 | 1.10 | 0.50 | 2.40 | 41 | 2000 | 4×0.80 | 1.72 | 42 | 2579 | 2 | 1.88 | 45 | 3350 | 249 | 282 | 500 |
185/95 | Stranded | 1.60 | 1.10 | 0.50 | 2.60 | 46.50 | 2550 | 4×0.80 | 1.88 | 47.20 | 3166 | 2.50 | 2.04 | 50 | 4381 | 282 | 329 | 500 |
240/120 | Stranded | 1.70 | 1.20 | 0.60 | 2.80 | 52.50 | 3200 | 4×0.80 | 2.04 | 52.70 | 3913 | 2.50 | 2.20 | 56 | 5313 | 327 | 392 | 500 |
300/150 | Stranded | 1.80 | 1.40 | 0.60 | 3 | 56 | 4000 | 4×0.80 | 2.20 | 57 | 4716 | 2.50 | 2.50 | 56 | 6254 | 369 | 452 | 250 |
400/185 | Stranded | 2 | 1.70 | 0.70 | 3.40 | 64 | 5250 | 4×0.80 | 2.52 | 65 | 6000 | 3.15 | 2.50 | 61 | 8300 | 420 | 526 | 500 |
500/240 | Stranded | 2.20 | 1.70 | 0.70 | 3.60 | 72.50 | 6500 | 4×0.80 | 2.68 | 73.50 | 7400 | 3.15 | 2.84 | 77 | 9880 | 478 | 612 | 250 |
Nominal Size of Conductor | Form of Conductor Circular Shaped | Nominal Thickness of XLPE Insulation | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 13.50 | 160 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.30 | 413 | 35 | 32 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 14.20 | 180 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 435 | 35 | 32 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 14.70 | 200 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16.50 | 473 | 46 | 42 | 1000 |
6 | Stranded o | 0.70 | 0.30 | 1.80 | 15.50 | 215 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17.30 | 506 | 46 | 42 | 1000 |
10 | Solid o | 0.70 | 0.30 | 1.80 | 16.60 | 250 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.40 | 18.60 | 592 | 57 | 54 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 17.50 | 260 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.40 | 19.80 | 633 | 57 | 54 | 1000 |
16 | Stranded | 0.70 | 0.30 | 1.80 | 17.80 | 350 | 4*0.80 | 1.40 | 20 | 624.50 | 1.60 | 1.40 | 21 | 795 | 74 | 69 | 1000 |
25 | Stranded | 0.90 | 0.30 | 2 | 21 | 550 | 4*0.80 | 1.40 | 23 | 828.50 | 1.60 | 1.40 | 25 | 1062 | 95 | 93 | 500 |
35 | Stranded | 0.90 | 0.30 | 2 | 23.50 | 680 | 4*0.80 | 1.40 | 25 | 1015.50 | 1.60 | 1.40 | 26.50 | 1259 | 114 | 114 | 500 |
50 | Stranded | 1 | 0.30 | 2 | 26 | 875 | 4*0.80 | 1.56 | 28 | 1275 | 1.60 | 1.56 | 29.50 | 1581 | 134 | 138 | 500 |
70 | Stranded | 1.10 | 0.40 | 2.20 | 30.50 | 1200 | 4*0.80 | 1.56 | 32 | 1656.40 | 2 | 1.56 | 34 | 2175 | 164 | 175 | 500 |
95 | Stranded | 1.10 | 0.40 | 2.20 | 33.50 | 1530 | 4*0.80 | 1.56 | 35 | 2041.90 | 2 | 1.72 | 38 | 2695 | 197 | 216 | 500 |
120 | Stranded | 1.20 | 0.50 | 2.40 | 37.50 | 1850 | 4*0.80 | 1.72 | 39 | 2442.50 | 2 | 1.88 | 42 | 3241 | 223 | 249 | 500 |
150 | Stranded | 1.40 | 0.50 | 2.60 | 42 | 2280 | 4*0.80 | 1.88 | 43 | 2929.90 | 2.50 | 2.04 | 47 | 4167 | 249 | 284 | 500 |
185 | Stranded | 1.60 | 0.50 | 2.80 | 46.50 | 2800 | 4*0.80 | 2.04 | 48 | 3563.10 | 2.50 | 2.20 | 52 | 4928 | 282 | 329 | 500 |
240 | Stranded | 1.70 | 0.60 | 3 | 52.50 | 3700 | 4*0.80 | 2.20 | 54 | 4464.30 | 2.50 | 2.36 | 57.50 | 5998 | 327 | 292 | 500 |
300 | Stranded | 1.80 | 0.70 | 3.20 | 58 | 4600 | 4*0.80 | 2.36 | 59.50 | 5359.50 | 3.15 | 2.52 | 64.50 | 7722 | 369 | 452 | 500 |
400 | Stranded | 2 | 0.70 | 3.60 | 65.50 | 6000 | 4*0.80 | 2.68 | 66.50 | 6749.30 | 3.15 | 2.84 | 71.50 | 9487 | 420 | 526 | 500 |