The HRFR and HRFR-LSH wires from RBICAB are premium-quality electrical wires engineered to meet modern industrial and commercial wiring standards. These wires are heat-resistant, fire-retardant (HRFR), and low-smoke halogen-free (LSH), making them the perfect choice for safe, reliable, and long-lasting electrical installations across residential, commercial, and industrial environments.
Built with high-grade copper conductors, they deliver excellent conductivity with minimal power loss. The PVC insulation ensures superior mechanical strength while offering resistance to heat, moisture, and chemical exposure. In addition, the low-smoke halogen-free design minimizes the emission of toxic fumes during fire incidents, enhancing overall safety for both people and equipment.
RBICAB’s HRFR and HRFR-LSH wires are versatile and suitable for multiple applications such as panel board wiring, internal building wiring, control circuits, and installations in sensitive or high-risk areas. They strictly comply with IS:694:2010 standards and come with the ISI mark, guaranteeing quality, durability, and complete regulatory compliance.
Nominal Voltage (U0/U): 600/1100 V
Max Operating Temperature: 85°C
Temperature Range: -15°C to +85°C
Approvals: IS 8130:2013
Flammability: IEC 60332-1:2004
Minimum Bending Radius: 8D
Oxygen Index: Minimum 29%
Temperature Index: Minimum 250°C
Area in sq.mm | Cond. Dia. in mm | Cable Dia (Approx) | Max. DC Resistance Ohm/km @ 20°C | Current Rating (Amp) | Area in sq.mm | Cond. Dia. in mm | Max. DC Resistance Ohm/km @ 20°C | Cable Dia (Approx) | Current Rating (Amp) |
0.5 | 0.94 | 2.20 | 39.00 | 4 | 70 | 12.3 | 0.272 | 15.50 | 170 |
0.75 | 1.20 | 2.50 | 26.00 | 7 | 95 | 14.7 | 0.206 | 18.50 | 210 |
1.0 | 1.34 | 2.60 | 19.50 | 11 | 120 | 16.70 | 0.161 | 20.90 | 235 |
1.5 | 1.64 | 2.90 | 13.30 | 14 | 150 | 18.3 | 0.129 | 22.50 | 295 |
2.5 | 2.08 | 3.50 | 7.98 | 19 | 185 | 20.00 | 0.106 | 24.60 | 330 |
4.0 | 2.61 | 4.30 | 4.95 | 26 | 240 | 23.00 | 0.0801 | 27.60 | 400 |
6.0 | 3.50 | 5.30 | 3.3 | 33 | 300 | 27 | 0.0641 | 32.20 | 475 |
10.0 | 4.60 | 6.70 | 1.910 | 45 | 400 | 30.5 | 0.0486 | 35.70 | 550 |
16.0 | 6.0 | 8.20 | 1.21 | 60 | 500 | 32 | 0.0384 | 38.00 | 635 |
25.0 | 7.60 | 10.00 | 0.780 | 75 | 630 | 39.00 | 0.0287 | 45.50 | 725 |
35.0 | 8.70 | 11.30 | 0.554 | 95 | 800 | 44 | 0.0178 | 51.00 | 840 |
50.0 | 10.60 | 13.50 | 0.386 | 125 | 1000 | 46 | 0.0178 | 53.00 | 950 |
Conductor Area (sq.mm) | No. / Dia of Strand (mm) | Approx Overall Diameter (mm) | Current Carrying Capacity (Amps) | Max. Resistance @ 20°C (Ohm/km) |
1.00 | 1/1.2 | 2.70 | 11 | 18.10 |
1.50 | 3/0.80 | 3.20 | 13 | 12.10 |
2.50 | 3/1.04 | 3.90 | 18 | 7.41 |
4.00 | 7/0.85 | 4.25 | 24 | 4.61 |
6.00 | 7/1.04 | 4.95 | 31 | 3.08 |
10.00 | 7/1.35 | 6.30 | 42 | 1.83 |
16.00 | 7/1.70 | 7.30 | 57 | 1.15 |
25.00 | 7/2.14 | 9.00 | 74 | 0.727 |
35.00 | 7/2.54 | 10.00 | 90 | 0.524 |
50.00 | 19/1.78 | 12.00 | 123 | 0.387 |
CONDUCTOR | INSULATION | ||||||
AREA | NO. & SIZE OF WIRE | DIAMETER OF WIRE | MAX. RESISTANCE AT 20°C | DC OR SINGLE PHASE AC SEPARATE IN AIR | NOMINAL THICKNESS | NOMINAL OVERALL DIAMETER | |
SQ. MM | MM | MM | OHM/KM | AMPS | MM | MM | |
0.50 | 16/.20 | 0.95 | 37.50 | 4 | 0.6 | 2.30 | |
0.75 | 24/.20 | 1.24 | 25.00 | 6 | 0.6 | 2.55 | |
1.00 | 32/.20 | 1.31 | 18.70 | 10 | 0.6 | 2.70 | |
1.50 | 48/.20 | 1.64 | 13.00 | 15 | 0.6 | 2.95 | |
2.50 | 80/.20 | 2.08 | 7.98 | 20 | 0.7 | 3.65 | |
4.00 | 128/.20 | 2.64 | 4.95 | 25 | 0.8 | 4.35 | |
6.00 | 85/.30 | 3.20 | 3.124 | 46 | 0.8 | 5.65 | |
10.0 | 140/.30 | 4.60 | 1.88 | 64 | 1.0 | 7.15 | |
16.0 | 101/.45 | 5.90 | 1.140 | 85 | 1.4 | 8.95 | |
25.0 | 168/.45 | 7.60 | 0.721 | 112 | 1.4 | 10.65 | |
35.0 | 220/.45 | 8.70 | 0.525 | 138 | 1.4 | 11.75 | |
50.0 | 325/.45 | 10.60 | 0.362 | 172 | 1.6 | 14.05 | |
70.0 | 440/.45 | 12.30 | 0.261 | 214 | 1.8 | 16.15 | |
95.0 | 485/.50 | 14.70 | 0.195 | 254 | 1.9 | 18.75 | |
120.0 | 614/.50 | 16.70 | 0.152 | 300 | 2.1 | 21.25 | |
150.0 | 943/.45 | 18.30 | 0.125 | 340 | 2.2 | 22.50 | |
185.0 | 925/.50 | 20.30 | 0.101 | 390 | 2.5 | 25.50 | |
240.0 | 1221/.50 | 23.00 | 0.076 | 460 | 2.5 | 28.50 | |
CONDUCTOR | INSULATION | ||||||
CROSS SECTIONAL | NO. & SIZE OF WIRE | COPPER C.R. AT 20°C | ALUMINIUM CAPACITY COPPER | CURRENT CARRYING THICKNESS | NOMINAL THICKNESS OF INSULATION | NOMINAL OVERALL DIAMETER | |
CU | AL | ||||||
SQ. MM. | MM. | OHM / KM. | OHM / KM. | AMPS. | AMPS. | MM. | MM. |
1.0 | 1/1.12 | 17.70 | – | 18 | – | 0.7 | 2.55 |
1.5 | 1/1.38 | 11.90 | 19.7 | 25 | 20 | 0.7 | 2.80 |
2.5 | 1/1.78 | 7.14 | 11.8 | 32 | 25 | 0.8 | 3.40 |
4.0 | 1/2.24 | 4.47 | 7.39 | 45 | 35 | 0.8 | 3.85 |
6.0 | 1/2.76 | 2.97 | 4.91 | 55 | 45 | 0.8 | 4.40 |
10.0 | 1/3.57 | 1.77 | 2.94 | 75 | 60 | 1.0 | 5.60 |
16.0 | 7/1.70 | 1.12 | 1.89 | 95 | 75 | 1.0 | 7.10 |
25.0 | 7/2.14 | 0.710 | 1.17 | 125 | 100 | 1.2 | 8.85 |
30.0 | 7/2.52 | 0.520 | 0.861 | 150 | 120 | 1.2 | 9.90 |
50.0 | 19/1.78 | 0.360 | 0.595 | 190 | 150 | 1.4 | 11.90 |
70.0 | 19/2.14 | 0.265 | 0.373 | 240 | 185 | 1.4 | 13.50 |
95.0 | 19/2.52 | 0.190 | 0.250 | 280 | 215 | 1.6 | 15.70 |
120.0 | 37/2.03 | 0.151 | 0.211 | 300 | 240 | 1.6 | 17.40 |
150.0 | 37/2.24 | 0.121 | 0.195 | 350 | 270 | 1.8 | 19.30 |
Nominal Area (sq.mm) | No. of Strands / Wire Dia. (mm) | Overall Dia. (mm) | Current Carrying Capacity (Amp) |
10 | 80 / 0.30 | 6.5 | 70 |
16 | 126 / 0.30 | 7.5 | 100 |
25 | 196 / 0.30 | 9.5 | 135 |
35 | 276 / 0.30 | 11.0 | 170 |
50 | 396 / 0.30 | 13.0 | 215 |
70 | 540 / 0.30 | 15.0 | 280 |
95 | 765 / 0.30 | 17.0 | 340 |
120 | 1026 / 0.30 | 19.5 | 400 |