As one of the leading manufacturers of Domestic & Industrial Electric Wires and Cables in India, we have always believed in setting higher benchmarks of quality, safety, and reliability.
RBICAB Fire Detection Cables are specialized for accurate and rapid signal transmission in automatic fire detection and early warning systems. Meeting international fire safety standards, these cables ensure that incipient fire signals are communicated instantly and reliably to control panels, enabling swift evacuation and firefighting response in critical environments.
Utilizing oxygen-free copper conductors and insulated with fire-resistant, low-smoke, zero-halogen materials, RBICAB fire detection cables offer exceptional performance during fire events. They are tested to maintain circuit integrity under high temperatures, allowing detectors, aspirating systems, flame sensors, and gas detectors to function until emergency shutdown or evacuation is complete.
RBICAB provides fire detection cables in shielded and unshielded forms for addressable and conventional fire alarm loops, beam detectors, duct detectors, and monitoring modules. The rugged outer sheath withstands high heat, mechanical impact, moisture, and chemical exposure. Easy to route and install in false ceilings, risers, ducts, and hazardous areas, these cables are specified for airports, petrochemical plants, power stations, hospitals, tunnels, and heritage buildings.
Parameter | Specification |
|---|---|
Brand | RBICAB |
Conductor Material | 99.97% Pure Annealed Copper |
Conductor Type | Solid / Stranded (Class 2 as per IEC 60228) |
Available Sizes | 0.5, 0.75, 1.0, 1.5, 2.5 sq.mm (others on request) |
Insulation Material | PVC / FRLS / HRFR / LSZH |
Insulation Thickness | 0.6 mm to 0.8 mm |
Core Identification | Red-Black, Red-White, Red (Single Core), Custom Colors |
Number of Cores | 1C / 2C / 3C / 4C / 6C / 8C / 12C |
Shielding (Optional) | Aluminium Mylar Tape with Tinned Copper Drain Wire |
Outer Sheath Material | PVC (FR / FRLS / HRFR) / LSZH |
Outer Sheath Color | Red (Standard), White / Black / Grey (Optional) |
Sheath Thickness | 0.9 mm to 1.2 mm |
Rated Voltage | 300/500V or 450/750V |
Test Voltage | 2.0 kV for 1 minute |
Temperature Range | -20°C to +85°C (PVC), -30°C to +105°C (LSZH) |
Insulation Resistance | > 1 GΩ/km at 20°C |
Fire Standards | IEC 60332-1, IEC 60332-3, IEC 60754, IEC 61034, BS 7629 / BS 6387 (optional), UL 1424 (optional) |
Construction Types | Unshielded, Shielded, Armoured (Optional) |
Applications | Fire Alarm Systems, Smoke/Heat Detectors, PA Systems, Emergency Lighting, Fire Panels, Sprinkler Systems |
D-18, Site-3, Meerut Road Industrial Area, UPSIDC, Ghaziabad, Uttar Pradesh 201003 (INDIA)