RBICAB Aluminium Armoured Cables are premium-grade electrical cables engineered to deliver secure and robust power transmission in demanding environments. Featuring a high-strength aluminium conductor, these cables offer excellent electrical conductivity while maintaining a lightweight profile for easier handling and installation.
The key feature of RBICAB Armoured Cables is their protective metallic armour layer, typically constructed from galvanized steel wires or strips. This armour provides superior mechanical protection against physical damage, crushing, rodent attacks, moisture, and chemical exposure, making them ideal for underground burial, direct burial, outdoor installations, industrial plants, and areas with high risk of mechanical stress.
Manufactured in compliance with stringent international standards such as IEC, IS, and BS, these cables ensure operational safety, fire resistance, and long-term reliability. They are extensively used in power distribution networks, substations, mining operations, infrastructure projects, and renewable energy farms where durability and protection are paramount.
RBICAB Aluminium Armoured Cables provide a cost-effective and efficient solution for heavy-duty electrical applications, combining the economic benefits of aluminium with the resilience of steel armour for uninterrupted power delivery.
Feature / Application | Details |
|---|---|
Conductor Material | High-purity aluminium for lightweight, excellent conductivity, and efficient power transmission |
Cable Type | Armoured for mechanical protection (galvanized steel or aluminium) or unarmoured for indoor flexibility |
Insulation Material | PVC, XLPE, or other high-performance compounds resistant to heat, moisture, chemicals, and fire |
Primary Uses | Power distribution, industrial plants, renewable energy systems, commercial complexes, and infrastructure projects |
Mechanical Protection | Armoured cables protect against mechanical stress, impact, rodent attacks, and harsh environmental conditions |
Installation Environment | Indoor wiring, cable trays, panels, overhead installations, and outdoor underground deployments |
Durability | High mechanical strength, corrosion resistance, and long service life |
Standards Compliance | Manufactured as per IEC, IS, BS, and other international standards |
Performance | Ensures safe, efficient, and reliable power transmission with minimal energy loss |
Nominal Size of Conductor | Form of Conductor Circular | Nominal Thickness of XLPE Insulation For U/A | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Nominal Thickness of XLPE Insulation For Armoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating (Amps) | Normal Delivery Length (mtrs) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of Aluminium Round Wire | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||||
mm | mm | mm | mm | mm | Kgs./Km | mm | mm | mm | mm | Kgs./Km | mm | mm | mm | Kgs./Km | Amps. | Amps. | Mtrs. | |
4 | Solid | 0.70 | -NA- | 1.80 | 7.50 | 60 | - | - | - | - | - | - | - | - | - | 43 | 38 | 1000 |
4 | Stranded | 0.70 | -NA- | 1.80 | 8 | 65 | - | - | - | - | - | - | - | - | - | 43 | 38 | 1000 |
6 | Solid | 0.70 | -NA- | 1.80 | 8 | 70 | - | - | - | - | - | - | - | - | - | 55 | 50 | 1000 |
6 | Standard | 0.70 | -NA- | 1.80 | 8.50 | 75 | - | - | - | - | - | - | - | - | - | 55 | 50 | 1000 |
10 | Solid | 0.70 | -NA- | 1.80 | 9 | 80 | 1 | - | - | - | - | - | - | - | - | 69 | 64 | 1000 |
10 | Standard | 0.70 | -NA- | 1.80 | 9.50 | 90 | 1 | - | - | - | - | - | - | - | - | 69 | 64 | 1000 |
16 | Standard | 0.70 | -NA- | 1.80 | 10 | 115 | 1 | - | - | - | - | 1.40 | 1.24 | 13 | 193.30 | 69 | 64 | 1000 |
25 | Standard | 0.90 | -NA- | 1.80 | 12 | 155 | 1.20 | - | - | - | - | 1.40 | 1.24 | 14 | 250 | 115 | 112 | 1000 |
35 | Standard | 0.90 | -NA- | 1.80 | 13 | 180 | 1.20 | - | - | - | - | 1.40 | 1.24 | 15 | 293.40 | 137 | 137 | 1000 |
50 | Stranded | 1 | -NA- | 1.80 | 14 | 240 | 1.30 | - | - | - | - | 1.40 | 1.24 | 17 | 353.5 | 161 | 165 | 1000 |
70 | Stranded | 1.10 | -NA- | 1.80 | 16 | 310 | 1.40 | - | - | - | - | 1.40 | 1.24 | 19 | 443 | 198 | 209 | 1000 |
95 | Stranded | 1.10 | -NA- | 1.80 | 17.50 | 385 | 1.40 | 4x0.80 | 1.40 | 18.60 | 498.81 | 1.60 | 1.40 | 20.20 | 572.30 | 243 | 264 | 1000 |
120 | Stranded | 1.20 | -NA- | 1.80 | 19 | 470 | 1.50 | 4x0.80 | 1.40 | 20.40 | 606.34 | 1.60 | 1.40 | 23.50 | 678.74 | 276 | 308 | 1000 |
150 | Stranded | 1.40 | -NA- | 2 | 21.50 | 600 | 1.70 | 4x0.80 | 1.40 | 23 | 716.08 | 1.60 | 1.40 | 24.50 | 795.36 | 308 | 350 | 1000 |
185 | Stranded | 1.60 | -NA- | 2 | 23.50 | 710 | 1.90 | 4x0.80 | 1.40 | 25 | 866.86 | 1.60 | 1.40 | 26.50 | 947.06 | 349 | 406 | 1000 |
240 | Stranded | 1.70 | -NA- | 2 | 26 | 900 | 2 | 4x0.80 | 1.40 | 26.60 | 1055.79 | 1.60 | 1.40 | 29 | 1147.15 | 404 | 480 | 1000 |
300 | Stranded | 1.80 | -NA- | 2 | 28.50 | 1158 | 2.10 | 4x0.80 | 1.56 | 29.60 | 1294.16 | 1.60 | 1.56 | 31.50 | 1389.30 | 454 | 451 | 1000 |
400 | Stranded | 2 | -NA- | 2.20 | 33 | 1385 | 2.40 | 4x0.80 | 1.56 | 33.20 | 1624.42 | 2 | 1.56 | 36.50 | 1813.29 | 518 | 647 | 500 |
500 | Stranded | 2.20 | -NA- | 2.20 | 36 | 1650 | 2.60 | 4x0.80 | 1.56 | 36.70 | 1997.06 | 2 | 1.56 | 39.50 | 2213.57 | 588 | 751 | 500 |
630 | Stranded | 2.40 | -NA- | 2.20 | 40 | 2100 | 2.80 | 4x0.80 | 1.72 | 40.50 | 2469.72 | 2 | 1.72 | 43 | 2698.20 | 663 | 868 | 500 |
800 | Stranded | 2.60 | -NA- | 2.40 | 43.70 | 2730 | 3.10 | 4x0.80 | 1.72 | 46.50 | 2986.96 | 2 | 1.88 | 47.90 | 3279.82 | 740 | 992 | 550 |
1000 | Stranded | 2.80 | -NA- | 2.60 | 49.20 | 3350 | 3.30 | 4x0.80 | 1.88 | 50.60 | 3742.01 | 2.50 | 2.04 | 54.37 | 4220.31 | 812 | 1117 | 500 |
Nominal Size of Cable | 3, 3.5 & 4 Core PVC Insulated & Sheathed Cables | 3, 3.5 & 4 Core XLPE Insulated & Sheathed Cables | ||||
|---|---|---|---|---|---|---|
In Ground | In Air | Approx Voltage Drop | In Ground | In Air | Approx Voltage Drop | |
Amp | Amp | Mv/amp/mtr | Amp | Amp | Mv/amv/mtr | |
16 | 61 | 52 | 4.00 | 74 | 69 | 4.20 |
25 | 78 | 70 | 2.50 | 94 | 93 | 2.70 |
35 | 94 | 85 | 1.80 | 114 | 114 | 1.90 |
50 | 111 | 104 | 1.30 | 134 | 175 | 1.40 |
70 | 136 | 131 | 1.00 | 167 | 175 | 0.99 |
95 | 163 | 156 | 0.68 | 197 | 216 | 0.72 |
120 | 185 | 186 | 0.54 | 223 | 249 | 0.58 |
150 | 206 | 212 | 0.43 | 249 | 284 | 0.48 |
185 | 234 | 245 | 0.38 | 282 | 329 | 0.41 |
240 | 271 | 291 | 0.28 | 327 | 392 | 0.31 |
300 | 305 | 335 | 0.25 | 369 | 452 | 0.29 |
400 | 348 | 390 | 0.20 | 420 | 526 | 0.21 |
Nominal Size of Conductor | Minimum no. of wires | Max D.C. Resistance at 20°C | A.C. Resistance at 90°C | |||||
|---|---|---|---|---|---|---|---|---|
Non Compacted | Compacted | Plain Copper | Aluminium | Plain Copper | Aluminium | |||
Round/Shaped | ||||||||
CU. | ALU. | CU. | ALU. | Ohm/Km | Ohm/Km | Ohm/Km | Ohm/Km | |
1.5* | 3 | 3 | - | - | 12.10 | 18.1 | 15.50 | 23.17 |
2.5* | 3 | 3 | - | - | 7.41 | 12.1 | 9.48 | 15.50 |
4* | 7 | 3 | - | - | 4.61 | 7.41 | 5.90 | 9.48 |
6* | 7 | 3 | - | - | 3.08 | 4.61 | 3.94 | 5.90 |
10* | 7 | 7 | 6 | - | 1.83 | 3.08 | 2.34 | 3.94 |
16 | 7 | 7 | 6 | 6 | 1.15 | 1.91 | 1.47 | 2.44 |
25 | 7 | 7 | 6 | 6 | 0.727 | 1.20 | 0.93 | 1.54 |
35 | 7 | 7 | 6 | 6 | 0.524 | 0.868 | 0.671 | 1.11 |
50 | 19 | 19 | 6 | 6 | 0.387 | 0.641 | 0.495 | 0.82 |
70 | 19 | 19 | 12 | 12 | 0.268 | 0.443 | 0.343 | 0.567 |
95 | 19 | 19 | 15 | 15 | 0.193 | 0.32 | 0.247 | 0.410 |
120 | 37 | 37 | 18 | 15 | 0.153 | 0.253 | 0.196 | 0.324 |
150 | 37 | 37 | 18 | 15 | 0.124 | 0.206 | 0.159 | 0.264 |
185 | 37 | 37 | 30 | 30 | 0.0991 | 0.164 | 0.127 | 0.210 |
240 | 61 | 37 | 34 | 30 | 0.0754 | 0.125 | 0.0965 | 0.160 |
300 | 61 | 61 | 34 | 30 | 0.0601 | 0.100 | 0.0769 | 0.128 |
400 | 61 | 61 | 53 | 53 | 0.047 | 0.0778 | 0.0602 | 0.100 |
500 | 61 | 61 | 53 | 53 | 0.0366 | 0.0605 | 0.0468 | 0.0774 |
630 | 91 | 91 | 53 | 53 | 0.0283 | 0.0469 | 0.0362 | 0.0600 |
800 | 91 | 91 | 53 | 53 | 0.0221 | 0.0367 | 0.0283 | 0.0470 |
Nominal Size of Conductor | Form of Conductor Circular Shaped O/Q | Nominal Thickness of XLPE Insulation For U/A | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of Aluminium Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of Aluminium Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 12.50 | 140 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 14.50 | 400 | 42 | 38 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 13 | 150 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.50 | 430 | 42 | 38 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 13.50 | 170 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.50 | 470 | 55 | 50 | 1000 |
6 | Stranded o | 0.70 | 0.30 | 1.80 | 14 | 180 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16.50 | 485 | 55 | 50 | 1000 |
10 | Solid o | 0.70 | 0.30 | 1.80 | 15 | 205 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17 | 545 | 68 | 64 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 16 | 225 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18 | 565 | 68 | 64 | 1000 |
16 | Stranded Q | 0.70 | 0.30 | 1.80 | 14 | 225 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.20 | 17 | 480.16 | 89 | 83 | 1000 |
25 | Stranded Q | 0.90 | 0.30 | 2 | 17 | 330 | 4x0.80 | 1.40 | 18.50 | 509.13 | 1.60 | 1.40 | 20 | 671.84 | 114 | 109 | 1000 |
35 | Stranded Q | 0.90 | 0.30 | 2 | 19 | 410 | 4x0.80 | 1.40 | 20 | 605.51 | 1.60 | 1.40 | 22 | 775.55 | 136 | 133 | 1000 |
50 | Stranded Q | 1 | 0.30 | 2 | 21 | 510 | 4x0.80 | 1.40 | 22.50 | 753.28 | 1.60 | 1.40 | 24 | 937.97 | 161 | 162 | 1000 |
70 | Stranded Q | 1.10 | 0.30 | 2 | 23 | 675 | 4x0.80 | 1.56 | 22.50 | 971 | 1.60 | 1.56 | 27 | 1188.85 | 197 | 204 | 1000 |
95 | Stranded Q | 1.10 | 0.40 | 2.20 | 26.50 | 900 | 4x0.80 | 1.56 | 28 | 1204.30 | 2 | 1.56 | 28.68 | 1572.78 | 235 | 251 | 1000 |
120 | Stranded Q | 1.20 | 0.40 | 2.20 | 28.50 | 1050 | 4x0.80 | 1.56 | 30.50 | 1408.20 | 2 | 1.56 | 33 | 1849.49 | 266 | 287 | 500 |
150 | Stranded Q | 1.40 | 0.40 | 2.20 | 32 | 1215 | 4x0.80 | 1.72 | 31.79 | 1690.20 | 2 | 1.72 | 36 | 2182.96 | 296 | 328 | 500 |
185 | Stranded Q | 1.60 | 0.50 | 2.40 | 35.50 | 1510 | 4x0.80 | 1.72 | 34.95 | 2025.90 | 2 | 1.88 | 37.70 | 2597.60 | 335 | 379 | 500 |
240 | Stranded Q | 1.70 | 0.50 | 2.60 | 39.50 | 1900 | 4x0.80 | 1.88 | 38.69 | 2500.60 | 2.50 | 2.04 | 45 | 3418.52 | 385 | 448 | 500 |
300 | Stranded Q | 1.80 | 0.60 | 2.80 | 43.50 | 2360 | 4x0.80 | 2.04 | 42.53 | 2992.20 | 2.50 | 2.20 | 46.22 | 4019.07 | 432 | 513 | 500 |
400 | Stranded Q | 2 | 0.60 | 3 | 49 | 3100 | 4x0.80 | 2.36 | 48.24 | 3790.21 | 2.50 | 2.36 | 51.61 | 4880.51 | 487 | 593 | 500 |
500 | Stranded Q | 2.20 | 0.70 | 3.40 | 55.50 | 4000 | 4x0.80 | 2.52 | 56.50 | 5000 | 3.15 | 2.68 | 61.50 | 7000 | 548 | 683 | 500 |
630 | Stranded | 2.40 | 0.70 | 3.60 | 61.50 | 5000 | 4x0.80 | 2.68 | 62.50 | 6050 | 3.15 | 2.84 | 67.50 | 8560 | 612 | 784 | 500 |
Nominal Size of Conductor | Form of Conductor Circular Shaped O/zs | Nominal Thickness of XLPE Insulation | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 14 | 140 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15 | 460 | 35 | 32 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 15.50 | 160 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 510 | 35 | 32 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 15.50 | 170 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 530 | 46 | 42 | 1000 |
6 | Stranded ^ | 0.70 | 0.30 | 1.80 | 16 | 190 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17 | 580 | 46 | 42 | 1000 |
10 | Solid ^ | 0.70 | 0.30 | 1.80 | 17 | 220 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18 | 640 | 57 | 54 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 18 | 230 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 18.50 | 680 | 57 | 54 | 1000 |
16 | Stranded ^ | 0.70 | 0.30 | 1.80 | 16.20 | 310 | 4x0.80 | 1.24 | 16.80 | 487.60 | 1.60 | 1.40 | 19 | 648.40 | 74 | 69 | 1000 |
25 | Stranded ^ | 0.90 | 0.30 | 2 | 19.50 | 460 | 4x0.80 | 1.40 | 20.10 | 670.70 | 1.60 | 1.40 | 21.70 | 863.30 | 95 | 93 | 1000 |
35 | Stranded ^ | 0.90 | 0.30 | 2 | 21.50 | 573.80 | 4x0.80 | 1.40 | 22 | 800.60 | 1.60 | 1.40 | 23.60 | 1015.80 | 114 | 114 | 1000 |
50 | Stranded ^ | 1 | 0.30 | 2 | 24.50 | 700 | 4x0.80 | 1.40 | 24.80 | 993.7 | 1.60 | 1.56 | 26.80 | 1259.60 | 134 | 138 | 1000 |
70 | Stranded ^ | 1.10 | 0.40 | 2.20 | 28 | 990 | 4x0.80 | 1.56 | 28.50 | 1299.60 | 2 | 1.56 | 30.90 | 1740.10 | 164 | 175 | 500 |
95 | Stranded ^ | 1.10 | 0.40 | 2.20 | 30.80 | 1250 | 4x0.80 | 1.56 | 31.30 | 1603 | 2 | 1.56 | 33.70 | 2117 | 197 | 216 | 500 |
120 | Stranded ^ | 1.20 | 0.40 | 2.20 | 33.80 | 1525 | 4x0.80 | 1.56 | 34.30 | 1914.10 | 2 | 1.72 | 37 | 2506.50 | 223 | 249 | 500 |
150 | Stranded ^ | 1.40 | 0.50 | 2.40 | 37.90 | 1895.90 | 4x0.80 | 1.72 | 38.30 | 2100 | 2 | 1.88 | 41.10 | 2988.80 | 249 | 284 | 500 |
185 | Stranded ^ | 1.60 | 0.50 | 2.60 | 42 | 2349.30 | 4x0.80 | 1.88 | 42.30 | 2500 | 2.50 | 2.04 | 46 | 3867.40 | 282 | 329 | 500 |
240 | Stranded ^ | 1.70 | 0.60 | 2.80 | 46.90 | 2981.40 | 4x0.80 | 2.04 | 47.20 | 3459.80 | 2.50 | 2.20 | 50.90 | 4677.30 | 327 | 392 | 500 |
300 | Stranded ^ | 1.80 | 0.60 | 3 | 51.50 | 3615.80 | 4x0.80 | 2.20 | 51.80 | 4150.20 | 2.50 | 2.36 | 55.45 | 5491.40 | 369 | 452 | 500 |
400 | Stranded ^ | 2 | 0.70 | 3.20 | 58.60 | 4650.10 | 4x0.80 | 2.52 | 58.50 | 5250.60 | 3.15 | 2.68 | 64 | 7401.40 | 420 | 526 | 500 |
500 | Stranded ^ | 2.20 | 0.70 | 3.60 | 66 | 6000 | 4x0.80 | 2.68 | 67 | 6900 | 3.15 | 2.84 | 73 | 9550 | 478 | 612 | 250 |
630 | Stranded ^ | 2.40 | 0.70 | 3.80 | 72 | 7550 | 4x0.80 | 2.84 | 73 | 8700 | 4 | 3 | 78 | 12500 | 542 | 712 | 250 |
Nominal Size of Conductor | Form of Conductor Circular Shaped | Nominal Thickness of XLPE Insulation Main / Neutral | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | ||||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | ||
25/16 | Stranded | 0.90 | 0.70 | 0.30 | 2 | 21.30 | 525 | 4×0.80 | 1.40 | 21.90 | 733 | 1.60 | 1.40 | 23.60 | 971 | 95 | 93 | 1000 |
35/16 | Stranded | 0.90 | 0.70 | 0.30 | 2 | 23.60 | 625 | 4×0.80 | 1.40 | 24.20 | 886 | 1.60 | 1.40 | 25.80 | 1139 | 114 | 114 | 1000 |
50/25 | Stranded | 1 | 0.90 | 0.40 | 2 | 26.80 | 800 | 4×0.80 | 1.40 | 27.40 | 1113 | 1.60 | 1.56 | 29.50 | 1419 | 134 | 138 | 1000 |
70/35 | Stranded | 1.10 | 0.90 | 0.40 | 2.20 | 31 | 1100 | 4×0.80 | 1.56 | 31.50 | 1451 | 2 | 1.56 | 34 | 1989 | 164 | 175 | 500 |
95/50 | Stranded | 1.20 | 1.00 | 0.40 | 2.20 | 34.30 | 1400 | 4×0.80 | 1.56 | 34.80 | 1796 | 2 | 1.56 | 37.20 | 2382 | 197 | 216 | 500 |
120/70 | Stranded | 1.20 | 1.10 | 0.40 | 2.20 | 37.50 | 1650 | 4×0.80 | 1.72 | 38.50 | 2199 | 2 | 1.72 | 41 | 2800 | 223 | 249 | 500 |
150/70 | Stranded | 1.40 | 1.10 | 0.50 | 2.40 | 41 | 2000 | 4×0.80 | 1.72 | 42 | 2579 | 2 | 1.88 | 45 | 3350 | 249 | 282 | 500 |
185/95 | Stranded | 1.60 | 1.10 | 0.50 | 2.60 | 46.50 | 2550 | 4×0.80 | 1.88 | 47.20 | 3166 | 2.50 | 2.04 | 50 | 4381 | 282 | 329 | 500 |
240/120 | Stranded | 1.70 | 1.20 | 0.60 | 2.80 | 52.50 | 3200 | 4×0.80 | 2.04 | 52.70 | 3913 | 2.50 | 2.20 | 56 | 5313 | 327 | 392 | 500 |
300/150 | Stranded | 1.80 | 1.40 | 0.60 | 3 | 56 | 4000 | 4×0.80 | 2.20 | 57 | 4716 | 2.50 | 2.50 | 56 | 6254 | 369 | 452 | 250 |
400/185 | Stranded | 2 | 1.70 | 0.70 | 3.40 | 64 | 5250 | 4×0.80 | 2.52 | 65 | 6000 | 3.15 | 2.50 | 61 | 8300 | 420 | 526 | 500 |
500/240 | Stranded | 2.20 | 1.70 | 0.70 | 3.60 | 72.50 | 6500 | 4×0.80 | 2.68 | 73.50 | 7400 | 3.15 | 2.84 | 77 | 9880 | 478 | 612 | 250 |
Nominal Size of Conductor | Form of Conductor Circular Shaped | Nominal Thickness of XLPE Insulation | Minimum Thickness of PVC Inner Sheath | Unarmoured Cable | Formed Wire / Strip Armoured Cable | Round Wire Armoured Cable | Current Rating. * | *Normal Delivery Length | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight of cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | Nominal Dimension of GI Flat Strip | Minimum Thickness of PVC Outer Sheath | Approx Overall Diameter Of Cable | Approx Weight Of Cable | In Ground | In Air | |||||
mm | mm | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | mm | mm | mm | Kgs/Km | Amps. | Amps. | Mtrs. | |
4 | Solid o | 0.70 | 0.30 | 1.80 | 13.50 | 160 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 15.30 | 413 | 35 | 32 | 1000 |
4 | Stranded o | 0.70 | 0.30 | 1.80 | 14.20 | 180 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16 | 435 | 35 | 32 | 1000 |
6 | Solid o | 0.70 | 0.30 | 1.80 | 14.70 | 200 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 16.50 | 473 | 46 | 42 | 1000 |
6 | Stranded o | 0.70 | 0.30 | 1.80 | 15.50 | 215 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.24 | 17.30 | 506 | 46 | 42 | 1000 |
10 | Solid o | 0.70 | 0.30 | 1.80 | 16.60 | 250 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.40 | 18.60 | 592 | 57 | 54 | 1000 |
10 | Stranded o | 0.70 | 0.30 | 1.80 | 17.50 | 260 | -NA- | -NA- | -NA- | -NA- | 1.40 | 1.40 | 19.80 | 633 | 57 | 54 | 1000 |
16 | Stranded | 0.70 | 0.30 | 1.80 | 17.80 | 350 | 4*0.80 | 1.40 | 20 | 624.50 | 1.60 | 1.40 | 21 | 795 | 74 | 69 | 1000 |
25 | Stranded | 0.90 | 0.30 | 2 | 21 | 550 | 4*0.80 | 1.40 | 23 | 828.50 | 1.60 | 1.40 | 25 | 1062 | 95 | 93 | 500 |
35 | Stranded | 0.90 | 0.30 | 2 | 23.50 | 680 | 4*0.80 | 1.40 | 25 | 1015.50 | 1.60 | 1.40 | 26.50 | 1259 | 114 | 114 | 500 |
50 | Stranded | 1 | 0.30 | 2 | 26 | 875 | 4*0.80 | 1.56 | 28 | 1275 | 1.60 | 1.56 | 29.50 | 1581 | 134 | 138 | 500 |
70 | Stranded | 1.10 | 0.40 | 2.20 | 30.50 | 1200 | 4*0.80 | 1.56 | 32 | 1656.40 | 2 | 1.56 | 34 | 2175 | 164 | 175 | 500 |
95 | Stranded | 1.10 | 0.40 | 2.20 | 33.50 | 1530 | 4*0.80 | 1.56 | 35 | 2041.90 | 2 | 1.72 | 38 | 2695 | 197 | 216 | 500 |
120 | Stranded | 1.20 | 0.50 | 2.40 | 37.50 | 1850 | 4*0.80 | 1.72 | 39 | 2442.50 | 2 | 1.88 | 42 | 3241 | 223 | 249 | 500 |
150 | Stranded | 1.40 | 0.50 | 2.60 | 42 | 2280 | 4*0.80 | 1.88 | 43 | 2929.90 | 2.50 | 2.04 | 47 | 4167 | 249 | 284 | 500 |
185 | Stranded | 1.60 | 0.50 | 2.80 | 46.50 | 2800 | 4*0.80 | 2.04 | 48 | 3563.10 | 2.50 | 2.20 | 52 | 4928 | 282 | 329 | 500 |
240 | Stranded | 1.70 | 0.60 | 3 | 52.50 | 3700 | 4*0.80 | 2.20 | 54 | 4464.30 | 2.50 | 2.36 | 57.50 | 5998 | 327 | 292 | 500 |
300 | Stranded | 1.80 | 0.70 | 3.20 | 58 | 4600 | 4*0.80 | 2.36 | 59.50 | 5359.50 | 3.15 | 2.52 | 64.50 | 7722 | 369 | 452 | 500 |
400 | Stranded | 2 | 0.70 | 3.60 | 65.50 | 6000 | 4*0.80 | 2.68 | 66.50 | 6749.30 | 3.15 | 2.84 | 71.50 | 9487 | 420 | 526 | 500 |